{"id":35184,"date":"2012-02-27T00:00:47","date_gmt":"2012-02-26T23:00:47","guid":{"rendered":"http:\/\/www.olino.org\/?p=35184"},"modified":"2012-02-26T21:10:43","modified_gmt":"2012-02-26T20:10:43","slug":"van-mechanische-ventilatie-naar-co2-vraaggestuurde-ventilatie","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/nl\/articles\/2012\/02\/27\/van-mechanische-ventilatie-naar-co2-vraaggestuurde-ventilatie\/","title":{"rendered":"Van mechanische ventilatie naar CO2 vraaggestuurde ventilatie"},"content":{"rendered":"<figure id=\"attachment_36161\" aria-describedby=\"caption-attachment-36161\" style=\"width: 59px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/02\/itho-co2-green-first.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"size-thumbnail wp-image-36161\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/02\/itho-co2-green-first-59x100.jpg\" alt=\"\" width=\"59\" height=\"100\" srcset=\"https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-co2-green-first-59x100.jpg 59w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-co2-green-first-239x400.jpg 239w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-co2-green-first-613x1024.jpg 613w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-co2-green-first.jpg 1552w\" sizes=\"(max-width: 59px) 100vw, 59px\" \/><\/a><figcaption id=\"caption-attachment-36161\" class=\"wp-caption-text\">De CO2 sensor<\/figcaption><\/figure>\n<p>Sinds 2008 draait hier in de nieuwbouwwoning (bouwjaar 2005) de Itho Ecofan 2. Initieel alleen met de bestaande drie-standenschakelaar op de badkamer, later voorzien van een tweede radiografische drie-standenschakelaar (met timer). Door de jaren heen zie en hoor je nog meer over de soorten van ventilatiesystemen en begint het toch te kriebelen om je ouderwetse &#8216;mechanische ventilatie&#8217; om te bouwen naar een modernere, energiezuinigere variant gebaseerd op vraagsturing.<\/p>\n<p>En zo begon dit project&#8230;<br \/>\n<!--more--><\/p>\n<p>Allereerst laat ik even nogmaals benadrukken dat mijn ventilatiekanalen en de afzuigventielen ingeregeld zijn ten tijde van de mechanische ventilatie periode met de Ecofan 2 door een bedrijf.<\/p>\n<p>Hier kon ik met de oude driestanden-schakelaar ventileren tussen 75 m3\/u, 150 m3\/u of maximal 300 m3\/u. Daarbij wordt naar rato een vastgesteld debiet van de woonkamer\/keuken, toilet en badkamer afgevoerd.<\/p>\n<h3>Energieverbruik &amp; EPC<\/h3>\n<p>Door de ventilatie vraaggestuurd te maken gebruik ik 1 enkele sensor in de referentie-ruimte. In mijn geval de woonkamer &amp; keuken. Om de luchtkwaliteit te meten wordt het gehalte CO2 continue in de gaten gehouden. Afhankelijk van hoeveel mensen er zijn, des te sneller het CO2 niveau zal stijgen en waar de ventilatie versneld in werking gaat treden.<\/p>\n<p>Bij afwezigheid zal de ventilatie blijven werken, tot het gewenste niveau bereikt is en dan stoppen met ventileren.<\/p>\n<p>Door het gepast ventileren wordt er geen overbodige warmte (uit de lucht) vervroegd weggevoerd, iets wat hopelijk zijn positieve invloed zal hebben op het gasverbruik in mijn huishouden.<\/p>\n<p>Afhankelijk van wat ik zoal gelezen heb, heeft een vraaggestuurde ventilatie een reductie op het EPC (energieprestatieco\u00ebfficient) van de woning in Nederland met een waarde van ca 0,1 tot 0,2.<\/p>\n<p>Ik heb ook gekeken naar de optie van een gebalanceerd ventilatiesysteem (waarbij \u00a0er een WTW (Warmteterugwinning) plaats vindt op de lucht). Helaas gaat dat niet zo makkelijk: het dient o.a. frees\/sloopwerk om aanvoer-en retourkanalen in de wanden\/vloeren weg te werken. En ik durf dan niet te garanderen dat de constructie voldoende stevig is als de vloerdelen zo verzwakt worden. Daarnaast is daarmee ook het kostenplaatje enorm, niet iets wat je even doet op een weekendje. Daarom het alternatief: van gewone mechanische ventilatie naar CO2-vraaggestuurde ventilatie.<\/p>\n<p>De CO2-sensor dient wel met een aparte voeding gevoed te worden. Het betreft hier een 15 Volt voeding. Gedurende de 2 weken van continue meten is er &#8230;. kWh verbruikt. Als verbruiksmeter is de voor handen zijnde Cresta RCE1106 hiervoor benut.<\/p>\n<h3>Aandachtspunten<\/h3>\n<h3>Benodigde materialen<\/h3>\n<figure id=\"attachment_36162\" aria-describedby=\"caption-attachment-36162\" style=\"width: 100px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-basic.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"size-thumbnail wp-image-36162\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-basic-100x59.jpg\" alt=\"\" width=\"100\" height=\"59\" srcset=\"https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-basic-100x59.jpg 100w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-basic-400x239.jpg 400w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-basic-1024x613.jpg 1024w\" sizes=\"(max-width: 100px) 100vw, 100px\" \/><\/a><figcaption id=\"caption-attachment-36162\" class=\"wp-caption-text\">De printplaat voor montage van de PWM-module t.b.v de CO2-sturing<\/figcaption><\/figure>\n<p>Voor de Itho Ecofan 2 zijn een aantal componenten noodzakelijk om een vraaggestuurde ventilatie te maken met behulp van een CO2-sensor.<\/p>\n<p>De CO2-sensor is rechtstreeks fysiek gekoppeld aan de Ecofan. Door continue meten van het CO2 niveau in de referentieruimte (bij mij de woonkamer en keuken) wordt bepaald hoe de luchtkwaliteit is.<\/p>\n<p>Grofweg is een CO2 niveau van meer dan 1.200 PPM niet langer meer hygienisch. Frisse en zuivere lucht bevat minder dan 500 PPM CO2.<\/p>\n<p>Door 5 LED&#8217;s op de CO2 sensor krijg je een indicatie wat er gemeten is in de ruimte:<\/p>\n<ul>\n<li>2e rode LED &gt;1600 PPM CO2<\/li>\n<li>1e rode LED 1200-1600 PPM CO2<\/li>\n<li>oranje\/gele LED 800-1200 PPM CO2<\/li>\n<li>1e groene LED 500-800 PPM CO2<\/li>\n<li>2e groene LED &lt;500 PPM CO2<\/li>\n<\/ul>\n<p>Afhankelijk van het niveau wat gemeten wordt door de CO2-sensor en de instelling op de sensor zelf (3 standen,<\/p>\n<figure id=\"attachment_36163\" aria-describedby=\"caption-attachment-36163\" style=\"width: 100px\" class=\"wp-caption alignright\"><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-PWM-print.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"size-thumbnail wp-image-36163\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-PWM-print-100x59.jpg\" alt=\"\" width=\"100\" height=\"59\" srcset=\"https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-PWM-print-100x59.jpg 100w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-PWM-print-400x239.jpg 400w, https:\/\/olino.org\/blog\/nl\/wp-content\/uploads\/2012\/02\/itho-ecofan-closeup-PWM-print-1024x613.jpg 1024w\" sizes=\"(max-width: 100px) 100vw, 100px\" \/><\/a><figcaption id=\"caption-attachment-36163\" class=\"wp-caption-text\">De PWM-module geplaatst (linkerzijde)<\/figcaption><\/figure>\n<p>ten behoeve van de aansturing naar de ventilatie) wordt er continue gemeten en geventileerd.<\/p>\n<p>De CO2-sensor heb ik op circa 160-170 cm hoogte gemonteerd, niet in de directe nabijheid van een afzuigpunt of luchttoevoerrooster.<\/p>\n<h3>Resultaten<\/h3>\n<p>Ik heb via de site <a href=\"http:\/\/www.mindergas.nl\" target=\"_blank\">Mindergas.nl<\/a> sinds het stookseizoen gestart is al enkele jaren aan gasverbruik vastgelegd, tot aan mijn referentie-jaar 2007.<\/p>\n<p>Door een vergelijk per periode (in dit geval: wekelijks) uit te voeren op basis van gewogen graaddagen is enig vergelijk mogelijk. Immers: het huishouden is constant gebleven, net als het leefpatroon. Het gas-aandeel voor het koken is minimaal, ca. 10 m3 op jaarbasis. Want het gros doe ik vooral elektrisch met o.a. een oven, magnetron en waterkoker.<\/p>\n<p>Aangezien er vele punten veranderd zijn ten opzicht van mijn oorspronkelijke basisjaar 2007, heb ik gekozen voor een vergelijk tussen 2012 en 2011. In dat jaar is o.a. de Atag Qsolar aanwezig, zijn alle ventilatie-ventielen op eenzelfde stand ingeregeld, en is ook de centrale verwarming waterzijdig ingeregeld. Enige verschil is dan nog de manier van ventileren: in 2011 nog gewoon met de normale driestanden-schakelaar, en vanaf eind januari 2012 op vraaggestuurde wijze via een CO2-sensor. In 2012 (vanaf 28 januari) is de CO2-vraaggestuurde regeling actief, en is deze ter visualisering vetgedrukt in onderstaande tabel weergegeven.<\/p>\n<table style=\"background-color: #ffffcc\" border=\"1\" cellspacing=\"3\" cellpadding=\"3\" width=\"400\">\n<tbody>\n<tr>\n<td>Tijdvak\/periode<\/td>\n<td>2011<\/p>\n<p>[m3\/gew.grd.dg]<\/td>\n<td>2012<\/p>\n<p>[m3\/gew.grd.dg]<\/td>\n<\/tr>\n<tr>\n<td>7 jan t.m. 13 jan<\/td>\n<td>0,26<\/td>\n<td>0,26<\/td>\n<\/tr>\n<tr>\n<td>14 jan t.m. 20 jan<\/td>\n<td>0,34<\/td>\n<td>0,24<\/td>\n<\/tr>\n<tr>\n<td>21 jan t.m. 27 jan<\/td>\n<td>0,30<\/td>\n<td>0,29<\/td>\n<\/tr>\n<tr>\n<td>28 jan t.m. 3 febr<\/td>\n<td>0,41<\/td>\n<td><strong>0,23<\/strong><\/td>\n<\/tr>\n<tr>\n<td>4 febr t.m. 10 febr<\/td>\n<td>0,30<\/td>\n<td><strong>0,23<\/strong><\/td>\n<\/tr>\n<tr>\n<td>11 febr t.m. 17 febr<\/td>\n<td>0,25<\/td>\n<td><strong>0,25<\/strong><\/td>\n<\/tr>\n<tr>\n<td>18 febr t.m. 24 febr<\/td>\n<td>0,31<\/td>\n<td><strong>0,23<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Uiteraard heb ik voor later dit jaar (najaar 2012) weer een meet-periode gepland, om te zien of de gedane bevindingen consistent blijven.<\/p>\n<p>Momenteel merk ik op dat de grootste winsten geboekt worden in koude perioden. Immers het verschil tussen de binnentemperatuur en de buitentemperatuur is dan het grootst, waardoor ook de meeste energie dan via ventilatie verdwijnt. En natuurlijk het geluid: er vindt alleen ventilatie plaats zodra deze nodig is (gemeten door de sensor). Al met al een mooie uitbreiding van de veel gebruikte mechanische ventilatie!<\/p>\n<hr \/>\n<p><em>Niels Thijssen, <a title=\"Renewable Energy: NOW!\" href=\"http:\/\/www.renewable-energy-now.org\/\">website Renewable Energy: NOW!<\/a><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sinds 2008 draait hier in de nieuwbouwwoning (bouwjaar 2005) de Itho Ecofan 2. Initieel alleen met de bestaande drie-standenschakelaar op de badkamer, later voorzien van een tweede radiografische drie-standenschakelaar (met timer). Door de jaren heen zie en hoor je nog meer over de soorten van ventilatiesystemen en begint het toch te kriebelen om je ouderwetse [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[3],"tags":[118,183],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/posts\/35184"}],"collection":[{"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/comments?post=35184"}],"version-history":[{"count":16,"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/posts\/35184\/revisions"}],"predecessor-version":[{"id":36172,"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/posts\/35184\/revisions\/36172"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/media?parent=35184"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/categories?post=35184"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/nl\/wp-json\/wp\/v2\/tags?post=35184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}