{"id":13798,"date":"2013-03-31T09:18:45","date_gmt":"2013-03-31T13:18:45","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=13798"},"modified":"2013-07-02T03:44:57","modified_gmt":"2013-07-02T07:44:57","slug":"lumitext-endurance-test-20x-lumistring-led-modules-3-5050-sw57","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2013\/03\/31\/lumitext-endurance-test-20x-lumistring-led-modules-3-5050-sw57\/","title":{"rendered":"LumitexT &#8211; Endurance test 20x Lumistring LED modules (3-5050-SW57)"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2011\/11\/LumitexT_LumiString_20Modules.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-33666\" title=\"LumitexT_LumiString_20Modules\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2011\/11\/LumitexT_LumiString_20Modules-100x20.jpg\" alt=\"\" width=\"100\" height=\"20\" \/><\/a>LumitexT has put a set of 20 ledmodules called lumoBOX-XT in endurance test.<\/p>\n<p>This article presents the endurance test results. The test has run 10.000 hours and shows a behavior of first declining light output and then increasing again until initial level.<\/p>\n<p>See <a href=\"http:\/\/www.olino.org\/us\/articles\/2012\/02\/01\/lumitext-20x-lumistring-led-modules-3-5050-sw57\">here<\/a> the results of the 0-hours test.<\/p>\n<p><!--more--><\/p>\n<h3>Summary Measurement Data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>initially<\/th>\n<th>after 6000 hrs endurance<\/th>\n<th>after 10000 hrs endurance<\/th>\n<th>remarks<\/th>\n<\/tr>\n<tr>\n<td>Color Temperature<\/td>\n<td>6869 K<\/td>\n<td>6618 K<\/td>\n<td>6721 K<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Luminous Intensity I<sub>v<\/sub><\/td>\n<td>302.2 Cd<\/td>\n<td>258.6 Cd<\/td>\n<td>322.9 Cd<\/td>\n<td>See remarks at luminous flux<\/td>\n<\/tr>\n<tr>\n<td>Beam Angle<\/td>\n<td>121 deg<\/td>\n<td>121 deg<\/td>\n<td>121 deg<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>16.0 W<\/td>\n<td>15.7 W<\/td>\n<td>15.7 W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/26\/explaining-the-power-factor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.93<\/td>\n<td>0.93<\/td>\n<td>0.95<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Luminous Flux<\/td>\n<td>935 lm<\/td>\n<td>800 lm<\/td>\n<td>1006 K<\/td>\n<td>A reduction of flux as been measured initially during a significant amount of time after which it increased again.<\/td>\n<\/tr>\n<tr>\n<td>Luminous Efficacy<\/td>\n<td>59 lm\/W<\/td>\n<td>51 lm\/W<\/td>\n<td>64 lm\/W<\/td>\n<td>See remarks at luminous flux<\/td>\n<\/tr>\n<tr>\n<td>CRI_Ra<\/td>\n<td>77<\/td>\n<td>76<\/td>\n<td>77<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Coordinates Chromaticity Diagram<\/td>\n<td>x=0.3082 and y=0.3189<\/td>\n<td>x=0.3112 and y=0.3259<\/td>\n<td>x=0.3096 and y=0.3245<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Test duration and test environment<\/h3>\n<p>The lamp went into endurance test on 27 Oct 2011 until 22 Dec 2012.<\/p>\n<p>During this period of time the lamp has seen the following ambient  temperature and ambient relative humidity.<\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2011_09_2012_01.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-40553\" title=\"2011_09_2012_01\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2011_09_2012_01-400x243.png\" alt=\"\" width=\"400\" height=\"243\" \/><\/a><\/em><\/p>\n<p><em>Period Sept 2011 &#8211; Jan 2012.<br \/>\n<\/em><\/p>\n<p><em> <\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2012_01_31_2012_03_28.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" title=\"2012_01_31_2012_03_28\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2012_01_31_2012_03_28-400x242.png\" alt=\"\" width=\"400\" height=\"242\" \/><\/a><\/em><\/p>\n<p><em>Jan 2012 &#8211; Mar 2012.<\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2012_04_2012_07.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" title=\"2012_04_2012_07\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2012_04_2012_07-400x242.png\" alt=\"\" width=\"400\" height=\"242\" \/><\/a><\/em><\/p>\n<p><em>April 2012 &#8211; July 2012.<\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2012_07_2012_09.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" title=\"2012_07_2012_09\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/09\/2012_07_2012_09-400x242.png\" alt=\"\" width=\"400\" height=\"242\" \/><\/a><\/em><\/p>\n<p><em>July 2012 &#8211; Sept 2012.<\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/11\/2012_09_2012_11.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-42277\" title=\"2012_09_2012_11\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/11\/2012_09_2012_11-400x241.png\" alt=\"\" width=\"400\" height=\"241\" \/><\/a><\/em><\/p>\n<p><em>Sept 2012 &#8211; Nov 2012.<br \/>\n<\/em><\/p>\n<p>The ambient temperature close to the lamp varied between 14-32 deg C and the relative humidity between 15-80 %.<\/p>\n<h3>Variation of lamp parameters<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/DR_LumitexT_LumiString_20Modules_parameter_dependance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-45228\" title=\"DR_LumitexT_LumiString_20Modules_parameter_dependance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/DR_LumitexT_LumiString_20Modules_parameter_dependance-400x307.png\" alt=\"\" width=\"400\" height=\"307\" \/><\/a><\/p>\n<p><em>The variation of the lamp parameters during the endurance test.<\/em><\/p>\n<p>See the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/09\/13\/endurance-test-setup\" target=\"_blank\">explanation on the OliNo site<\/a> for more on the test method.<\/p>\n<p>No extrapolation to the 70 % level of the luminous flux is possible when using the illuminance as a measure for the luminous flux. The illuminance decreased at first and after 5000 hours started to increase until initial level.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/DR_LumitexT_LumiString_20Modules_illuminance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-45229\" title=\"DR_LumitexT_LumiString_20Modules_illuminance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/DR_LumitexT_LumiString_20Modules_illuminance-400x303.png\" alt=\"\" width=\"400\" height=\"303\" \/><\/a><\/p>\n<p><em>Extrapolation of the illuminance.<\/em><\/p>\n<p>See the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/09\/13\/endurance-test-setup\" target=\"_blank\">explanation on the OliNo site<\/a> for more explanation and the link to the ASSIST document for the method of extrapolation.<\/p>\n<p>The extrapolation of this data until 70 % of illuminance is reached could not be done as explained before.<\/p>\n<h3>Color change<\/h3>\n<p>The color change (change in color coordinates) is measured during the test period.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/2013_02_06_chromaticities_Lumistring.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-45230\" title=\"2013_02_06_chromaticities_Lumistring\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/2013_02_06_chromaticities_Lumistring-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>Change in color coordinates during the endurance test.<\/em><\/p>\n<p>The color coordinates indicated with the red cross-hairs are the  coordinates after 1000 burn hours. These are taken as reference. After 10000 hours the color point remains inside the 4-step McAdams ellipse.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>LumitexT has put a set of 20 ledmodules called lumoBOX-XT in endurance test. This article presents the endurance test results. The test has run 10.000 hours and shows a behavior of first declining light output and then increasing again until initial level. See here the results of the 0-hours test.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[32],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/13798"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=13798"}],"version-history":[{"count":9,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/13798\/revisions"}],"predecessor-version":[{"id":13801,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/13798\/revisions\/13801"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=13798"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=13798"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=13798"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}