{"id":14646,"date":"2013-06-25T19:09:15","date_gmt":"2013-06-25T23:09:15","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=14646"},"modified":"2013-06-25T19:09:15","modified_gmt":"2013-06-25T23:09:15","slug":"lumitext-endurance-test-20x-led-modules-lumistring-hlc2s","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2013\/06\/25\/lumitext-endurance-test-20x-led-modules-lumistring-hlc2s\/","title":{"rendered":"LumitexT &#8211; Endurance test 20x led modules LumiString HLC2S"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/LumitexT_20mLumiStringHLC2S.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-45479\" title=\"LumitexT_20mLumiStringHLC2S\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/02\/LumitexT_20mLumiStringHLC2S-100x27.jpg\" alt=\"\" width=\"100\" height=\"27\" \/><\/a>LumitexT has put a set of 20 ledmodules in endurance test.<\/p>\n<p>This article presents the endurance test results. The test has run 6.000 hours and shows a constant light output.<\/p>\n<p>See <a href=\"http:\/\/www.olino.org\/us\/articles\/2013\/02\/24\/lumitext-20x-led-modules-lumistring-hlc2s\">here<\/a> the results of the 0-hours test.<\/p>\n<p><!--more--><\/p>\n<h3>Summary Measurement Data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>initially<\/th>\n<th>after 6000 hrs endurance<\/th>\n<\/tr>\n<tr>\n<td>Color Temperature<\/td>\n<td>6536 K<\/td>\n<td>6528 K<\/td>\n<\/tr>\n<tr>\n<td>Luminous Intensity I<sub>v<\/sub><\/td>\n<td>227.2 Cd<\/td>\n<td>219.5 Cd<\/td>\n<\/tr>\n<tr>\n<td>Beam Angle<\/td>\n<td>121 deg<\/td>\n<td>118 deg<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>11.4 W<\/td>\n<td>11.4 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/26\/explaining-the-power-factor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.88<\/td>\n<td>0.89<\/td>\n<\/tr>\n<tr>\n<td>Luminous Flux<\/td>\n<td>692 lm<\/td>\n<td>660 lm<\/td>\n<\/tr>\n<tr>\n<td>Luminous Efficacy<\/td>\n<td>61 lm\/W<\/td>\n<td>58 lm\/W<\/td>\n<\/tr>\n<tr>\n<td>CRI_Ra<\/td>\n<td>75<\/td>\n<td>76<\/td>\n<\/tr>\n<tr>\n<td>Coordinates Chromaticity Diagram<\/td>\n<td>x=0.3128 and y=0.3269<\/td>\n<td>x=0.3129 and y=0.3263<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Test duration and test environment<\/h3>\n<p>The lamp went into endurance test on 5 Sept 2012 until 18 May 2013.<\/p>\n<p>During this period of time the lamp has seen the following ambient  temperature and ambient relative humidity.<\/p>\n<p><em> <\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/11\/2012_09_2012_11.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-42277\" title=\"2012_09_2012_11\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2012\/11\/2012_09_2012_11-400x241.png\" alt=\"\" width=\"400\" height=\"241\" \/><\/a><\/em><\/p>\n<p><em>Sept 2012 &#8211; Nov 2012.<\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/2012_11_2013_03.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-49284\" title=\"2012_11_2013_03\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/2012_11_2013_03-400x242.png\" alt=\"\" width=\"400\" height=\"242\" \/><\/a><\/em><\/p>\n<p>Nov 2012 &#8211; March 2013<\/p>\n<p>The ambient temperature close to the lamp varied between 8-27 deg C and the relative humidity between 25-73 %. No ambient data is available for months April, May, due to a problem with low battery for the temperature and RH sensor. However the ranges given will include the values for these months as well.<\/p>\n<h3>Variation of lamp parameters<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/lumistring_parameters.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-49285\" title=\"lumistring_parameters\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/lumistring_parameters-400x277.png\" alt=\"\" width=\"400\" height=\"277\" \/><\/a><\/p>\n<p><em>The variation of the lamp parameters during the endurance test.<\/em><\/p>\n<p>See the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/09\/13\/endurance-test-setup\" target=\"_blank\">explanation on the OliNo site<\/a> for more on the test method.<\/p>\n<p>No extrapolation to the 70 % level of the luminous flux is possible when using the illuminance as a measure for the luminous flux. The illuminance does not decrease after 1,000 hours.<\/p>\n<p>There is a small variation in illuminance, probably due to the tape getting loose behind some modules and that resulted in a shift of their angular position. Afterwards these modules were again put straight.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/Lumistring_illuminance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-49286\" title=\"Lumistring_illuminance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/Lumistring_illuminance-400x305.png\" alt=\"\" width=\"400\" height=\"305\" \/><\/a><\/p>\n<p><em>Extrapolation of the illuminance.<\/em><\/p>\n<p>See the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/09\/13\/endurance-test-setup\" target=\"_blank\">explanation on the OliNo site<\/a> for more explanation and the link to the ASSIST document for the method of extrapolation.<\/p>\n<p>The extrapolation of this data until 70 % of illuminance is reached could not be done as explained before.<\/p>\n<h3>Color change<\/h3>\n<p>The color change (change in color coordinates) is measured during the test period.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/lumistring_chromaticityData.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-49287\" title=\"lumistring_chromaticityData\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/06\/lumistring_chromaticityData-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>Change in color coordinates during the endurance test.<\/em><\/p>\n<p>The color coordinates indicated with the red cross-hairs are the  coordinates after 1000 burn hours. These are taken as reference. After 6,000 hours the color point remains almost inside an 1-step McAdams ellipse. This is a very good result for constancy of color.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>LumitexT has put a set of 20 ledmodules in endurance test. This article presents the endurance test results. The test has run 6.000 hours and shows a constant light output. See here the results of the 0-hours test.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[32],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/14646"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=14646"}],"version-history":[{"count":2,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/14646\/revisions"}],"predecessor-version":[{"id":14649,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/14646\/revisions\/14649"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=14646"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=14646"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=14646"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}