{"id":32850,"date":"2022-01-26T22:33:42","date_gmt":"2022-01-26T21:33:42","guid":{"rendered":"https:\/\/www.olino.org\/blog\/us\/?p=32850"},"modified":"2022-01-26T22:33:42","modified_gmt":"2022-01-26T21:33:42","slug":"olino-trio-lighting-wall-lamp-norman-with-philips-e27-10-5w-ww-clear","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2022\/01\/26\/olino-trio-lighting-wall-lamp-norman-with-philips-e27-10-5w-ww-clear\/","title":{"rendered":"OliNo &#8211; Trio Lighting Wall-lamp Norman with Philips E27 10.5W WW Clear"},"content":{"rendered":"<p><!-- settings: {\"locale\":\"us\", \"category\": \"light_measurements\"} -->Here OliNo bought a Normal Wall lamp and used a\u00a0<a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman.jpg\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman.jpg\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman-93x100.jpg\" alt=\"\" width=\"93\" height=\"100\" \/><\/a><a href=\"\/advice\/us\/lamps\/details\/6879?source=measurement\" target=\"_blank\" rel=\"nofollow\" class=\"liexternal\">Philips<\/a> LED lamp in it. The measurements from OliNo show that the lamp emits a warm white light with a color temperature of 2625 K. The lamp consumes 10.4 W and has a luminous flux of 578 lm. This results in an efficacy of 56 lm\/W. The lamps energy category label is G (2021).\u00a0Using <a href=\"https:\/\/www.olino.org\/blog\/us\/articles\/2022\/01\/26\/olino-philips-e27-10-5w-ww-clear\">this clear LED lamp<\/a> in this luminaire yields a light loss of 68 %.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the eulumdat file.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><\/p>\n<h3>Summary measurement data dated 2022-01-18<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>2625 K<\/td>\n<td>warm white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>123.4 Cd<\/td>\n<td>Measured straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulatie\">Illuminance modulation index<\/a><\/td>\n<td>0 %<\/td>\n<td>Measured with a light sensor looking at the lamp (angle not defined). Is a measure for the amount of flickering.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulatie\">SVM<\/a><\/td>\n<td>0.0<\/td>\n<td>Stroboscopic Visibility Measure, and must be &lt;= 0.9 (from September 1, 2024 &lt;= 0.4) at full-load for certain (O)LEDs per EU regulation 2019\/2020.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>154 deg<\/td>\n<td>148 deg is the beam angle for the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\" rel=\"noopener\">C0-C180-plane<\/a> (perpendicular to the length direction of the lamp) and 154 deg is the beam angle for the C90-C270 plane, which is along the length direction of the lamp. Flux code: 34 63 87 95 100 1 1 9 5.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>10.4 W<\/td>\n<td>The net power consumed.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\" rel=\"noopener\">Power Factor<\/a><\/td>\n<td>0.59<\/td>\n<td>An electrical load with this power factor means that for every 1 kWh net energy consumed, there has been 1.38 kVAhr for reactive energy.<\/td>\n<\/tr>\n<tr>\n<td>Displacement factor<\/td>\n<td>0.94<\/td>\n<td>The cosine of the phase angle between the fundamental harmonic of the mains supply voltage and the fundamental harmonic of the mains current (from EU 2019\/2020).<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>125 %<\/td>\n<td>Total Harmonic Distortion.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>578 lm<\/td>\n<td>Measured with photogoniometer, calculation done as described in LM79-08.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>56 lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EU2021label\">EU2021-label classification<\/a><\/td>\n<td>G<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient). This label is an update of the previous version, and compulsory from Sept 2021.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EU2013label\">EU2013-label classification<\/a><\/td>\n<td>A<\/td>\n<td>The energy class, from A++ (more efficient) to E (least efficient). This energy label will be replaced on September 21, 2021.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>81<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\" rel=\"noopener\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#TM30\" target=\"_self\">Rf_TM30<\/a><\/td>\n<td>82<\/td>\n<td>TM30-15 is an improved indicator (over CRI) of how well colors are rendered.<\/td>\n<\/tr>\n<tr>\n<td>Rg_TM30<\/td>\n<td>94<\/td>\n<td>Gamut Area Ratio.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.4636 en y=0.4076<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td>230V<\/td>\n<td>This lamp is connected directly to the grid voltage.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cLm\">Luminous flux for chicken<\/a><\/td>\n<td>956 cLm<\/td>\n<td>Total radiant flux adjusted by color sensitivity curve (from 350 &#8211; 780 nm) of chickens (Gallus domesticus).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#SP-ratio\">S\/P ratio<\/a><\/td>\n<td>1.2<\/td>\n<td>This factor indicates the amount of times more efficient the light of this light bulb is perceived under scotopic circumstances (low environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>D x H external dimensions<\/td>\n<td>300 mm x 330 mm<\/td>\n<td>External dimensions of the lamp.<\/td>\n<\/tr>\n<tr>\n<td>D x H luminous area<\/td>\n<td>160 mm x 68 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). It is the surface of the smallest cilinder that contains the white ball.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of illuminance measurements was 24.5 &#8211; 25.1 deg C.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: During the warmup time the illuminance varies during 17 minutes and decreases with 16 %.<br \/>\nDuring the warmup time the power varies during 8 minutes and decreases with 5 %.<br \/>\nThe variation in efficacy (calculated as indication by simply dividing the illuminance by the power) during the warming up is -11 %. A very high negative value indicates a significant decrease for instance due to heating up of the lamp (decrease of lifetime).<\/p>\n<p>At the end of the article an <a href=\"#foto\">additional photo<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Eff-variation<\/td>\n<td>-11 %<\/td>\n<td>This is the variation in efficacy (calculated as indication by simply dividing the illuminance by the power) during the warming up. A very high negative value indicates a significant decrease for instance due to heating up of the lamp (decrease of lifetime).<\/td>\n<\/tr>\n<tr>\n<td>Dimmable<\/td>\n<td>no\/not known<\/td>\n<td>Info from manufacturer.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#mell\"><br \/>\nMelanopic effect factor<\/a><\/td>\n<td>0.374<\/td>\n<td>According to norm DIN SPEC 5031-100:2015-08.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EML_R\">Melanopic Ratio<\/a><\/td>\n<td>0.31<\/td>\n<td>This ratio multiplied with the lux value gives the EML-value (Equivalent Melanopic Value), used in <a href=\"https:\/\/standard.wellcertified.com\/tables#\">table L2 of WELL std 2019-Q3<\/a>.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#blh\">Blue Light Hazard risk group<\/a><\/td>\n<td>0<\/td>\n<td>0=exempt, 1=low, 2 = moderate, 3=high risk. Indication value only for straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td>form factor<\/td>\n<td>other<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Efficiency loss luminaire<\/td>\n<td>62 %<\/td>\n<td>The lamp use din this luminaire has been measured. The luminous output of this luminaire divided by the output of the lamp alone is only 38 %. This is the light output ratio of the luminaire.\u00a0 The light loss then follows as 1 &#8211; 38 % = 62 %.<\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a class=\"liimagelink tickbox no_icon\" title=\"OliNo-TrioLightingWandlampNorman_eulumdat.ldt\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_eulumdat.ldt\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_eulumdat.ldt\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<tr>\n<td>IES file<\/td>\n<td><a class=\"liimagelink tickbox no_icon\" title=\"OliNo-TrioLightingWandlampNorman.IES\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman.ies\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman.IES\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"summary2\"><\/a>Overview table<\/h3>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_summary2.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_summary2.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_summary2.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_summary2-400x135.png\" alt=\"\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>Please note that this <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\" rel=\"noopener\">overview table<\/a> makes use of calculations, use this data with care as explained on the OliNo site.<\/p>\n<h3><a name=\"EU2021label\"><\/a>EU 2021 Energy label classification<\/h3>\n<p>These energy labels are in force since Sept 2021. They have been drawn up in accordance with the Commission Delegated Regulation (EU) 2019\/2015.<\/p>\n<p>It applies to light sources, with requirements for the x, y chromaticity coordinates (is fulfilled), the luminous flux (is fulfilled) and colour rendering index CRI (is fulfilled).These requirements are fulfilled.<\/p>\n<p>The energy efficiency class of light sources shall be determined on the basis of the total mains efficacy eta<sub>TM<\/sub>. This is calculated by dividing the declared useful luminous flux (578 lm, flux in a sphere (360\u00b0)) by the declared on-mode power consumption P<sub>on<\/sub> (10.4 W) and multiplying by the applicable factor F<sub>TM<\/sub> that depends on the light source type (1.000, type: Non-directional (NDLS) operating on mains (MLS)). The result is the total mains efficacy eta<sub>TM<\/sub> = 56 (lm\/W).<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_EU2021_label_color.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_EU2021_label_color.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_EU2021_label_color.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_EU2021_label_color-200x400.png\" alt=\"\" width=\"200\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label for this light source<\/em><\/p>\n<p><a class=\"liimagelink tickbox no_icon\" title=\"OliNo-TrioLightingWandlampNorman_EU2021-ClassG_Labels.zip\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_EU2021-ClassG_Labels.zip\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_EU2021-ClassG_Labels.zip\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/05\/zip.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><\/p>\n<p><em>Zip file containing the EU energy efficiency labels for this light source<\/em><\/p>\n<h3><a name=\"EU2013label\"><\/a>EU 2013 Energy label classification<\/h3>\n<p>Since Sept 2013 these <a href=\"http:\/\/www.olino.org\/us\/articles\/2013\/05\/11\/eu-energy-label-for-lamps-update-sept-2013\">labels<\/a> will be needed.<\/p>\n<p>Important for the energy classification are the corrected rated power and the useful luminous flux.<br \/>\nThe measured rated power is 10.4 W and might need to be corrected. The correction is dependent from the lamp type and whether or not the lamp control gear is included or not. The choice for this lamp is the following classification: <b>Lamps with own control gear (external or internal)<\/b>. As a result the corrected rated power becomes: 10.4 W.<br \/>\nThe luminous flux measured is 578 lm. The classification of this lamp needed to determine the useful flux is: <b>Non-directional lamps<\/b>. Then the useful flux becomes 578 lm. Now a reference power can be calculated.<\/p>\n<p>The energy efficiency coefficient is P_corr \/ P_ref = 0.21.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_EU2013_label_color.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_EU2013_label_color.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_EU2013_label_color.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_EU2013_label_color-192x400.png\" alt=\"\" width=\"192\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label for this lamp<\/em><\/p>\n<p><a class=\"liimagelink tickbox no_icon\" title=\"OliNo-TrioLightingWandlampNorman_EU-ClassA_Labels.zip\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_EU-ClassA_Labels.zip\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_EU-ClassA_Labels.zip\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2013\/05\/zip.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><\/p>\n<p><em>Zip file with 6 EU energy labels of this lamp<\/em><\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_position_lumFlux_Power_graph2013.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_position_lumFlux_Power_graph2013.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_position_lumFlux_Power_graph2013.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_position_lumFlux_Power_graph2013-400x206.png\" alt=\"\" width=\"400\" height=\"206\" \/><\/a><\/p>\n<p><em>The lamp&#8217;s performance in the lumen-Watt field, with the energy efficacy fields indicated.<br \/>\n<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\" rel=\"noopener\">light diagram<\/a> below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\" rel=\"noopener\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_light_diagram.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_light_diagram.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_light_diagram.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_light_diagram-400x400.png\" alt=\"\" width=\"400\" height=\"400\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>The light diagram indicates the beam in the C0-C180 plane (perpendicular to the length direction of the lamp) and in the plane perpendicular to that, the C90-C270 plane (along the length direction of the lamp).<\/p>\n<p>When using the Ev or Iv values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\" rel=\"noopener\">beam angle<\/a> can be computed, being 148 deg for the C0-C180 plane and 154 deg for the C90-C270 plane.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_eulumdat_3DLightPattern.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_eulumdat_3DLightPattern.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_eulumdat_3DLightPattern.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_eulumdat_3DLightPattern-400x360.png\" alt=\"\" width=\"400\" height=\"360\" \/><\/a><\/p>\n<p><em>Image of the light distribution pattern in 3D.<\/em><\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_Ev_dep_kantelhoek.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_Ev_dep_kantelhoek.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_Ev_dep_kantelhoek.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_Ev_dep_kantelhoek-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement results for each turn angle at that inclination angle. There normally are differences in illuminance values for different turn angles. However for further calculations the averaged values will be used.<\/p>\n<h3><a name=\"lichtstroom\"><\/a>Luminous flux<\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 578 lm.<\/p>\n<h3><a name=\"efficientie\"><\/a>Luminous efficacy<\/h3>\n<p>The luminous flux being 578 lm, and the consumed power of the lamp being 10.4 Watt, results in a luminous efficacy of 56 lm\/Watt.<\/p>\n<h3><a name=\"electrical\"><\/a>Electrical properties<\/h3>\n<table>\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>229.98 V AC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>0.077 A<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>10.4 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\" rel=\"noopener\">Apparent power<\/a> S<\/td>\n<td>17.7 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\" rel=\"noopener\">Power factor<\/a><\/td>\n<td>0.59<\/td>\n<\/tr>\n<tr>\n<td>Displacement factor DF<\/td>\n<td>0.94<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>EU 2019\/2020: For LED and OLED, DF &gt;= 0,5 at 5 W &lt; P<sub>on<\/sub> = 10 W, DF &gt;= 0,7 at 10 W &lt; P<sub>on<\/sub> = 25 W, DF &gt;= 0,9 at 25 W &lt; P<sub>on<\/sub>.<\/p>\n<p>Of this lamp the voltage across and the resulting current through it are measured and graphed.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_U_I_waveforms.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_U_I_waveforms.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_U_I_waveforms.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_U_I_waveforms-400x224.png\" alt=\"\" width=\"400\" height=\"224\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This current waveform has been checked on requirements posed by the norm IEC 61000-3-2:2018. This norm contains requirements for lamps with a power 5 W, 5 &#8211; 25 W and &gt; 25 W. This lamp consumes 10.4 W.<br \/>\nNOTE: standard only applies to lamps with supply voltages higher than 220 V AC.<\/p>\n<p>When power is from 5 to and including 25 W there are requirements for the current. At least one of the three requirements given below, must be passed.<\/p>\n<p>1) Requirement for harmonics and form of the current:<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_waveform_checked.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_waveform_checked.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_waveform_checked.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_waveform_checked-400x246.png\" alt=\"\" width=\"400\" height=\"246\" \/><\/a><\/p>\n<p><em>Requirements on the form of the current in IEC61000-3-2:2018<\/em><\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_5-25W_form_and_harmonics.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_5-25W_form_and_harmonics.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_5-25W_form_and_harmonics.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_5-25W_form_and_harmonics-400x220.png\" alt=\"\" width=\"400\" height=\"220\" \/><\/a><\/p>\n<p><em>The harmonics in the current compared to requirements in IEC61000-3-2:2018, that belong to the requirement of the form of the current.<\/em><\/p>\n<p>2) Harmonic currents less than power-threshold values:<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_5-25W_harmonics2power.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_5-25W_harmonics2power.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_5-25W_harmonics2power.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_5-25W_harmonics2power-400x220.png\" alt=\"\" width=\"400\" height=\"220\" \/><\/a><\/p>\n<p><em>The harmonics in the current compared with maximum values in mA per Watt, as given in IEC61000-3-2:2018.<\/em><\/p>\n<p>3) Maximum value for THD (= 70 %) and for harmonics:<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_5-25W_THD_and_harmonics.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_5-25W_THD_and_harmonics.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_5-25W_THD_and_harmonics.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_5-25W_THD_and_harmonics-400x220.png\" alt=\"\" width=\"400\" height=\"220\" \/><\/a><\/p>\n<p><em>The harmonics of the current compared to maximum levels in IEC61000-3-2:2018, these levels belong together with the requirement of the maximum THD value.<\/em><\/p>\n<p>The requirements in norm IEC61000-3-2:2018 are NOT met (note: standard only applies to lamps with supply voltages higher than 220 V AC).<\/p>\n<p>Note: the used lampvoltage in this test is clean enough to be able to well evaluate the results of the current harmonics according to this norm. Herewith the image showing the harmonic content of the voltage used.<\/p>\n<p><a href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_harmonics_voltage.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-186460\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_harmonics_voltage-400x220.png\" alt=\"\" width=\"400\" height=\"220\" \/><\/a><\/p>\n<p><em>Harmonics in the voltage waveform and checked against IEC61000-3-2:2018.<\/em><\/p>\n<h3><a name=\"kleurtemperatuur\"><\/a>Color temperature and Spectral power distribution<\/h3>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_FULL_powerspectrum_at_1m_distance.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_FULL_powerspectrum_at_1m_distance.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_FULL_powerspectrum_at_1m_distance.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_FULL_powerspectrum_at_1m_distance-400x199.png\" alt=\"\" width=\"400\" height=\"199\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is 2625 K which is warm white.<\/p>\n<p>This color temperature is measured straight underneath the light bulb. Below a graph showing the color temperature for different inclination angles.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_cct_function_of_incl.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_cct_function_of_incl.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_cct_function_of_incl.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_cct_function_of_incl-400x311.png\" alt=\"\" width=\"400\" height=\"311\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The color temperature is given for inclination angles up to 85 deg. Beyond that value the illuminance is lower than 10%% of Ev straight underneath the lamp, that it has not been used for color determination of the light.<\/p>\n<p>For the C0-C180 plane: the beam angle of 148 deg is equivalent to 73.8 deg inclination angle,which is the area where most of the light falls within. The maximum variation of color temperature in this inclination area is about 1 %.<\/p>\n<p>For the C90-C270 plane: the beam angle of 154 deg is equivalent to 76.9 deg inclination angle,which is the area where most of the light falls within. The maximum variation of color temperature in this inclination area is about 1 %.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_colorOverAngle.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_colorOverAngle.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_colorOverAngle.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_colorOverAngle-364x400.png\" alt=\"\" width=\"364\" height=\"400\" \/><\/a><\/p>\n<p><em>Color point dependent on inclination angle related to 2, 4 and 6 step MacAdam ellipse, for all angles within the beam angle (solid line) and for all angles where Ev dropped to 10 % value (dotted line)<\/em><\/p>\n<h3><a name=\"cLm\"><\/a>Luminous flux for chicken<\/h3>\n<p>The energy in the spectrum of the light of the lamp can be evaluated by the spectral sensitivity of the eye of chicken (N.B. Prescott and C.M. Wathes, 1999 and <a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2017\/11\/calculating_luminous_flux_and_lighting_levels_for_domesticated_mammals_and_birds.pdf\">J. E. Saunders, J. R. Jarvis and C. M. Wathes, 2008<\/a>).<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_cLux_spectra_at_1m_distance.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_cLux_spectra_at_1m_distance.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_cLux_spectra_at_1m_distance.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_cLux_spectra_at_1m_distance-400x232.png\" alt=\"\" width=\"400\" height=\"232\" \/><\/a><\/p>\n<p><em>The spectrum of the light, multiplied by the spectral sensitivity of the human eye and the eye of a chicken.<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter [unit]<\/th>\n<th>value<\/th>\n<th>explanation<\/th>\n<\/tr>\n<tr>\n<td>Luminous flux [lm]<\/td>\n<td>578<\/td>\n<td>The light of the lamp evaluated for a human eye.<\/td>\n<\/tr>\n<tr>\n<td>Luminous flux chicken [cLm]<\/td>\n<td>956<\/td>\n<td>The light of the lamp evaluated for the eye of a chicken.<\/td>\n<\/tr>\n<tr>\n<td>Factor from lux to cLux<\/td>\n<td>1.65<\/td>\n<td>With this factor, the lux value of this light can be converted to the cLux value.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"SP-ratio\"><\/a>S\/P ratio<\/h3>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_S_and_P_spectra_at_1m_distance.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_S_and_P_spectra_at_1m_distance.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_S_and_P_spectra_at_1m_distance.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_S_and_P_spectra_at_1m_distance-400x251.png\" alt=\"\" width=\"400\" height=\"251\" \/><\/a><\/p>\n<p><em>The power spectrum, sensitivity curves and resulting scotopic and photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\" rel=\"noopener\">S\/P ratio<\/a> of the light coming from this lamp is 1.2.<\/p>\n<h3><a name=\"kleursoort\"><\/a>Chromaticity diagram<\/h3>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_chromaticity.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_chromaticity.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_chromaticity.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_chromaticity-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\" rel=\"noopener\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The point of the light in this diagram is inside the area indicated with class B. The areas A and B indicate areas for <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\" rel=\"noopener\">signal lamps<\/a>.<\/p>\n<p>The color coordinates are x=0.4636 and y=0.4076.<\/p>\n<h3><a name=\"cri\"><\/a>Color Rendering Index (CRI) or also Ra<\/h3>\n<p>Herewith the image showing the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\" rel=\"noopener\">CRI<\/a> as well as how well different colors are represented (rendered). The higher the number, the better the resemblance with the color when a black body radiator would have been used (the sun, or an incandescent lamp)<\/p>\n<p>Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_cri.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_cri.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_cri.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_cri.png\" alt=\"\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>This value of 81 indicates how well the light of this lamp can render well a set of reference colors, this in comparison with the light of a reference source (for color temperatures 5000K a black radiator is used as reference and for color temperatures 5000K the sun or the light outside during the day).<\/p>\n<p>The value of 81 is bigger than the value of 80 that is considered as a minimum for working areas in general.<\/p>\n<p>Note: the chromaticity difference is -0.0014 and indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\" rel=\"noopener\">Planckian Locus<\/a>. There is a value mentioned of max 5.4E-3 in section 5.3 of CIE 13.3-1995 however no further explanation of it.<br \/>\nAn other reference with signal lights as a reference is given in the <a href=\"#kleursoort\" target=\"_self\">chromaticity<\/a> diagram.<\/p>\n<h3><a name=\"TM30\"><\/a>Color quality scale TM-30-15<\/h3>\n<p>TM-30-15 is an improved indicator (over CRI) of how well colors are rendered.<br \/>\nTM30-15 Rf = 82, Rg = 94.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_TM30-15_fidelityIndexGraphBig.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_TM30-15_fidelityIndexGraphBig.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_TM30-15_fidelityIndexGraphBig.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_TM30-15_fidelityIndexGraphBig-400x137.png\" alt=\"\" width=\"400\" height=\"137\" \/><\/a><\/p>\n<p><em>TM-30-15-values for 99 samples for the light of this light bulb. The closer the value for a testcolor comes to 100, the more its rendition resembles that of a reference lightsource.<\/em><\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_TM30-15_ClrVctrGrphc.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_TM30-15_ClrVctrGrphc.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_TM30-15_ClrVctrGrphc.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_TM30-15_ClrVctrGrphc.png\" alt=\"\" width=\"301\" height=\"307\" \/><\/a><\/p>\n<p><em>Graphical view of averaged color points for this light bulb compared to a reference source with the same color temperature.<\/em><\/p>\n<h3><a name=\"heatup-effect\"><\/a>Warm up effects<\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp is measured on illuminance E_v [lx], the lamppower P [W] and the luminous efficacy [lm\/W].<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_startupEffect.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_startupEffect.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_startupEffect.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_startupEffect-400x232.png\" alt=\"\" width=\"400\" height=\"232\" \/><\/a><\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_startupEffect_end.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_startupEffect_end.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_startupEffect_end.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_startupEffect_end-400x233.png\" alt=\"\" width=\"400\" height=\"233\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. In the first graph the 100 % level is put at begin, and in the last graph the 100 % level is put at the end.<\/em><\/p>\n<p>During the warmup time the illuminance varies during 17 minutes and decreases with 16 %.<br \/>\nDuring the warmup time the power varies during 8 minutes and decreases with 5 %.<br \/>\nThe variation in efficacy (calculated as indication by simply dividing the illuminance by the power) during the warming up is -11 %. A very high negative value indicates a significant decrease for instance due to heating up of the lamp (decrease of lifetime).<\/p>\n<h3><a name=\"mel\"><\/a>Melanopic effect<\/h3>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2016\/01\/20\/lighting-for-the-body-not-just-for-the-eyes\">melanopic effect<\/a> shows the level of impact the light of this lamp can have on the day-night rhythm of human beings (as well as the suppression of melatonin production).<br \/>\nThe important parameters (according to norm DIN SPEC 5031-100:2015-08):<\/p>\n<table>\n<tbody>\n<tr>\n<td>melanopic effect factor<\/td>\n<td>0.374<\/td>\n<\/tr>\n<tr>\n<td>k<sub>mel trans<\/sub> (25 years)<\/td>\n<td>1.042<\/td>\n<\/tr>\n<tr>\n<td>k<sub>mel trans<\/sub> (32 years)<\/td>\n<td>1.000<\/td>\n<\/tr>\n<tr>\n<td>k<sub>mel trans<\/sub> (50 years)<\/td>\n<td>0.862<\/td>\n<\/tr>\n<tr>\n<td>k<sub>mel trans<\/sub>(75 years)<\/td>\n<td>0.644<\/td>\n<\/tr>\n<tr>\n<td>k<sub>mel trans<\/sub>(90 years)<\/td>\n<td>0.520<\/td>\n<\/tr>\n<tr>\n<td>k<sub>pupil<\/sub>(25 years)<\/td>\n<td>1.088<\/td>\n<\/tr>\n<tr>\n<td>k<sub>pupil<\/sub>(32 years)<\/td>\n<td>1.000<\/td>\n<\/tr>\n<tr>\n<td>k<sub>pupil<\/sub>(50 years)<\/td>\n<td>0.792<\/td>\n<\/tr>\n<tr>\n<td>k<sub>pupil<\/sub>(75 years)<\/td>\n<td>0.543<\/td>\n<\/tr>\n<tr>\n<td>k<sub>pupil<\/sub>(90 years)<\/td>\n<td>0.416<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"CS\"><\/a>Circadian Stimulus (CS)<\/h3>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2018\/04\/06\/how-effective-is-light-on-the-circadian-rhythm-of-humans-use-the-cs\">circadian stimulus<\/a> indicates the degree of influence that the light of this lamp has on the human circadian rhythm. In addition to the melanopic effect of Ganglion cells, the contributions of S-cones and rods are also included. A CS value of 0.1 has hardly any effect and a value &gt; 0.3 has an effect (0.7 is the maximum, saturated, value). The CS value depends on the spectrum of the light and also on the amount of it (received on the eye).<\/p>\n<table>\n<tbody>\n<tr>\n<th>Ev [lux]<\/th>\n<th>CL_<sub>A<\/sub><\/th>\n<th>CS<\/th>\n<\/tr>\n<tr>\n<td>20.0<\/td>\n<td>16.7<\/td>\n<td>0.02<\/td>\n<\/tr>\n<tr>\n<td>30.0<\/td>\n<td>25.0<\/td>\n<td>0.04<\/td>\n<\/tr>\n<tr>\n<td>50.0<\/td>\n<td>41.7<\/td>\n<td>0.06<\/td>\n<\/tr>\n<tr>\n<td>75.0<\/td>\n<td>62.5<\/td>\n<td>0.09<\/td>\n<\/tr>\n<tr>\n<td>100.0<\/td>\n<td>83.4<\/td>\n<td>0.12<\/td>\n<\/tr>\n<tr>\n<td>150.0<\/td>\n<td>125.1<\/td>\n<td>0.17<\/td>\n<\/tr>\n<tr>\n<td>300.0<\/td>\n<td>250.2<\/td>\n<td>0.28<\/td>\n<\/tr>\n<tr>\n<td>500.0<\/td>\n<td>416.9<\/td>\n<td>0.38<\/td>\n<\/tr>\n<tr>\n<td>750.0<\/td>\n<td>625.4<\/td>\n<td>0.46<\/td>\n<\/tr>\n<tr>\n<td>1000.0<\/td>\n<td>833.8<\/td>\n<td>0.50<\/td>\n<\/tr>\n<tr>\n<td>1500.0<\/td>\n<td>1250.8<\/td>\n<td>0.56<\/td>\n<\/tr>\n<tr>\n<td>2000.0<\/td>\n<td>1667.7<\/td>\n<td>0.59<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"blh\"><\/a>Blue Light Hazard<\/h3>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2011\/09\/13\/blue-light-hazard-for-the-human-eye\" target=\"_blank\" rel=\"noopener\">amount of blue light<\/a> and the harm it can cause on the retina has been determined. Herewith the results.<\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_BLH_EL_in_W.m-2.sr-1.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_BLH_EL_in_W.m-2.sr-1.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_BLH_EL_in_W.m-2.sr-1.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_BLH_EL_in_W.m-2.sr-1-400x234.png\" alt=\"\" width=\"400\" height=\"234\" \/><\/a><\/p>\n<p><em>The level of blue light of this lamp related to the exposure limit and the different classification areas.<\/em><\/p>\n<table>\n<tbody>\n<tr>\n<td>L_lum0 [mm]<\/td>\n<td>151<\/td>\n<td>Dimension of brightest part of lamp in C0-C180 direction.<\/td>\n<\/tr>\n<tr>\n<td>L_lum90 [mm]<\/td>\n<td>151<\/td>\n<td>Dimension of brightest part of lamp in C90-C270 direction.<\/td>\n<\/tr>\n<tr>\n<td>SSD_500lx [mm]<\/td>\n<td>513<\/td>\n<td>Calculated distance where Ev = 500 lux. This computation is valid when it is in the far field of the lamp. Note: if this value 200 mm then the distance of 200 mm is taken as proposed in the norm IEC 62471:2006.<\/td>\n<\/tr>\n<tr>\n<td>Start of far field [mm]<\/td>\n<td>1068<\/td>\n<td>Minimum distance at which the lamp can be seen as a point source. In this area the Ev is linearly dependent from (1\/distance)<sup>2<\/sup>.<\/td>\n<\/tr>\n<tr>\n<td>300-350 nm values stuffed with 0s<\/td>\n<td>no<\/td>\n<td>In the event OliNo has measured with a SpB1211 spectrometer without UV option then the irradiance data of 300-349 nm is missing. For lamps where there is already no energy content near 350 nm, the values 300-349 can also be set at zero then.<\/td>\n<\/tr>\n<tr>\n<td>alpha<sub>C0-C180<\/sub> [rad]<\/td>\n<td>0.100<\/td>\n<td>(Apparent) source angle in C0-C180 direction.<\/td>\n<\/tr>\n<tr>\n<td>alpha<sub>C90-C270<\/sub> [rad]<\/td>\n<td>0.100<\/td>\n<td>(Apparent) source angle in C90-C270 direction.<\/td>\n<\/tr>\n<tr>\n<td>alpha<sub>AVG<\/sub> [rad]<\/td>\n<td>0.100<\/td>\n<td>Average (apparent) source angle. If average &gt;= 0.011 rad then the exposure limit is computed with radiance Lb. Otherwise with irradiance Eb.<\/td>\n<\/tr>\n<tr>\n<td>Exposure value [W\/m^2\/sr]<\/td>\n<td>1.76E+0<\/td>\n<td>Blue Light Hazard value for this lamp, measured straight underneath the lamp. Computation is referenced to Lb. Because the distance at 500 lux is in the near field, then this exposure value is too pessimistic and should be lower.<\/td>\n<\/tr>\n<tr>\n<td>Blue Light Hazard risk group<\/td>\n<td>0<\/td>\n<td>0=exempt, 1=low, 2 = moderate, 3=high risk.<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"foto\"><\/a>Extra<\/h3>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_meetopstelling.jpg\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_meetopstelling.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_meetopstelling.jpg\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_meetopstelling-400x285.jpg\" alt=\"\" width=\"400\" height=\"285\" \/><\/a><\/p>\n<p><a class=\"liimagelink tickbox no_icon thickbox\" title=\"OliNo-TrioLightingWandlampNorman_drawing.png\" href=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_drawing.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail\" title=\"OliNo-TrioLightingWandlampNorman_drawing.png\" src=\"https:\/\/www.olino.org\/blog\/nl\/wp-content\/uploads\/2022\/01\/OliNo-TrioLightingWandlampNorman_drawing-236x400.png\" alt=\"\" width=\"236\" height=\"400\" \/><\/a><\/p>\n<p><em>Additional photos.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Here OliNo bought a Normal Wall lamp and used a\u00a0 LED lamp in it. The measurements from OliNo show that the lamp emits a warm white light with a color temperature of 2625 K. The lamp consumes 10.4 W and has a luminous flux of 578 lm. This results in an efficacy of 56 lm\/W. [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/32850"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=32850"}],"version-history":[{"count":1,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/32850\/revisions"}],"predecessor-version":[{"id":32851,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/32850\/revisions\/32851"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=32850"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=32850"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=32850"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}