{"id":4482,"date":"2010-01-27T00:34:47","date_gmt":"2010-01-27T05:34:47","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=4482"},"modified":"2010-10-12T02:03:23","modified_gmt":"2010-10-12T07:03:23","slug":"greentubes-silverline-120cm-tl5","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/01\/27\/greentubes-silverline-120cm-tl5\/","title":{"rendered":"Greentubes SL12\/6500."},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-11620\" title=\"greentubes_silverline\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline-100x32.jpg\" alt=\"greentubes_silverline\" width=\"100\" height=\"32\" \/><\/a> Greentubes BV presents a 120 cm long tube light. It is a small fluorescent tube in a transparent plastic outer tube which serves as the housing. At the back side of the inner fluorescent tube a reflector is seated with a white color. At the back side (against the inner back side of the outer tube) a heat sink is positioned. The heat sink is seated inside the transparent plastic outer tube.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\" target=\"_blank\">Eulumdat file<\/a>.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>6629 K<\/td>\n<td>Cold white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>473 Cd<\/td>\n<td>Measured straight underneath the lamp<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>181 deg<\/td>\n<td>181\u00ba for the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C0-C180 plane<\/a> (crosses the length direction of the tube), and 107\u00ba for C90-C270 plane (along the length direction of tube).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#electrical\">Power P<\/a><\/td>\n<td>25.2 W<\/td>\n<td>Follow the link for more electrical and temperature properties.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.93<\/td>\n<td>For every 1 kWh net power consumed, there has been 0.4 kVAhr for reactive power.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>2036 Lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>81 Lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EUlabel\">EU-label classification<\/a><\/td>\n<td>A<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>84<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.3080 and y=0.3436<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Bipin\" target=\"_blank\">FL-tube<\/a><\/td>\n<td>This energy saving retrofit T5 tube is connected directly to the 230 V grid.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>4.3 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.7 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>2.3<\/td>\n<td>This factor indicates the amount of times more efficient the light of this light bulb is perceived under scotopic circumstances (ow environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>D x L external dimensions<\/td>\n<td>32 x 1196 mm<\/td>\n<td>External dimensions of the lamp (D = diameter, L = Length without pins).<\/td>\n<\/tr>\n<tr>\n<td>L x W x H luminous area<\/td>\n<td>1107 x 30 x 7 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is equal to the surface of area of the reflector and the height is the top hald of the fluorescent tube.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 23.5-25 deg C. The average temperature of the tube light gets <a href=\"#T_metingen\" target=\"_self\">about 16 degrees hotter<\/a> than ambient. The maximum temperature point was 25 degrees warmer.<br \/>\n<a href=\"#heatup-effect\">Warm up effect<\/a>: during the warm up time the illuminance increases to more than 200 % of the initial value.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: the power consumption and illuminance do linearly depend on the voltage when it is varied from 200 &#8211; 250 V.<\/td>\n<\/tr>\n<tr>\n<td>Measurement report (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2010\/01\/greentubes_silverline_eng.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_eulumdat.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-1887\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11622\" title=\"greentubes_silverline_120cm_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_summary2-400x135.png\" alt=\"greentubes_silverline_120cm_summary2\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website. Please note that this overview table makes use of calculations, use this data with care as explained on the OliNo site. E (lux) values are not accurate, when within 5 x 1107 mm \u2248 5500 mm. Within this distance from the lamp, the measured lux values willl be less than the computed values in this overview as the measurements are then within the near field of the lamp.<\/p>\n<p>Note II: the illuminated area (\u00f8 50%) in the C0-C180 plane is not relevant as the beam angle there is &gt;= 180\u00ba.<\/p>\n<h3><a name=\"EUlabel\">EU Energy label classfication<\/a><\/h3>\n<p>With the measurement results of the luminous flux and the consumed power the classification on energy of this lamp is calculated. This information is requested in the EU for certain household lamps, see also the  <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/12\/eu-energy-label-for-lamps\" target=\"_blank\">OliNo site<\/a> that explains for which lamps it is requested, how the label looks like and what information it needs to contain.<\/p>\n<p>Herewith the labels for this lamp in color and black and white.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/Greentubes-SL12-6500_EU_label_color.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19064\" title=\"Greentubes SL12 6500_EU_label_color\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/Greentubes-SL12-6500_EU_label_color-208x400.png\" alt=\"\" width=\"208\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label of this lamp<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/Greentubes-SL12-6500_EU_label_bw.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-19065\" title=\"Greentubes SL12 6500_EU_label_bw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/Greentubes-SL12-6500_EU_label_bw-52x100.png\" alt=\"\" width=\"52\" height=\"100\" \/><\/a><\/p>\n<p><em>Label in black and white.<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11623\" title=\"greentubes_silverline_120cm_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_light_diagram-400x312.png\" alt=\"greentubes_silverline_120cm_light_diagram\" width=\"400\" height=\"312\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. The direction C90-C270 has a smaller beam than the C0-C180. This latter emits in a wide angle.<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_pp_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11624\" title=\"greentubes_silverline_120cm_pp_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_pp_avg-392x400.png\" alt=\"greentubes_silverline_120cm_pp_avg\" width=\"392\" height=\"400\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the light diagram given earlier. Also, in this graph the luminous intensity is given in Cd.<\/p>\n<p>These averaged values are used (later) to compute the lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11625\" title=\"greentubes_silverline_120cm_ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_ev_dep_kantelhoek-400x211.png\" alt=\"greentubes_silverline_120cm_ev_dep_kantelhoek\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement results for each turn angle at that inclination angle. There normally are differences in illuminance values for different turn angles. However for further calculations the averaged values will be used.<\/p>\n<p>When using the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 181\u00ba for the C0-C180 plane (crossing the length direction) and 107\u00ba in the C90-C270 plane (along the length direction).<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 2036 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 2036 Lm, and the power of the light bulb being 25.2 W, yields a luminous efficacy of 81 Lm\/W.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>A power factor of 0.93 means that for every 1 kWh net power consumed, a reactive component of 0.4 kVAr was needed.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>118 mA<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>25.2 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>27.1 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>0.93<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">the OliNo site<\/a> how this is obtained.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_u_i_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11626\" title=\"greentubes_silverline_120cm_u_i_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_u_i_waveforms-400x222.png\" alt=\"greentubes_silverline_120cm_u_i_waveforms\" width=\"400\" height=\"222\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/01\/02\/background-thd-and-iec-61000-3-22006-results-in-lamp-measurement-articles\" target=\"_blank\">explanation on the OliNo website<\/a>.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_harmonics.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11627\" title=\"greentubes_silverline_120cm_harmonics\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_harmonics-400x219.png\" alt=\"greentubes_silverline_120cm_harmonics\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the current waveform and checked against IEC61000-3-2:2006<\/em><\/p>\n<p>There are limits for the harmonics for led lighting equipment &gt; 25 W. Some of these limits are not met, see the image for the indication of the frequencies. Further it will be shown that the 230 V grid voltage used is slightly out of required norm specification, which will have a deteriorating effect on the resulting current harmonics. Therefore this result of the harmonics in the current must not be interpreted as definite, but as a serious indication.<\/p>\n<p>The used grid voltage is also checked against the requirements in the norm.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_harmonics_voltage.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11630\" title=\"greentubes_silverline_120cm_harmonics_voltage\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_harmonics_voltage-400x219.png\" alt=\"greentubes_silverline_120cm_harmonics_voltage\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>The norm harmonic limits and the check of the voltage used<\/em><\/p>\n<p>The used grid voltage has slightly more harmonic content than the current prescribes. As the voltage ha smore harmonic content, then it will negatively affect the harmonics in the resulting current. The harmonic content in the current must therefore be seen as a serious indication.<\/p>\n<p>The Total Harmonic Distortion of the current is computed as 33 %.<\/p>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/ir_0285.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-11631\" title=\"ir_0285\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/ir_0285.jpg\" alt=\"ir_0285\" width=\"240\" height=\"240\" \/><\/a><\/p>\n<p><em>Temperature image\u00a0 (warmest side) of the light bulb<\/em><\/p>\n<p>Tape is put on the hottest side. The square in the image shows the temperature area on this tape. Also a measurement point is given of the hotspot near the tube end.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>24 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>24 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir B-CAM Western S<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>0.20 m<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.7 mm<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>100 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> The emissivity of the masking tape is used which is about 0.95. The masking tape is so thin that it quickly takes the same temperature as the light bulb&#8217;s heat sink.<\/p>\n<p>The tube on its hotttest side (approximately 40 degrees) gets no warmer than warm-to-the-touch. The hotspot seen gets to 49 deg C.<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11632\" title=\"greentubes_silverline_120cm_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_powerspectrum_at_1m_distance-400x211.png\" alt=\"greentubes_silverline_120cm_powerspectrum_at_1m_distance\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is about 6625 K which is cold white.<\/p>\n<p>This color temperature is measured straight underneath the light bulb. Below a graph showing the color temperature for different inclination angles.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_cct_function_of_incl.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11633\" title=\"greentubes_silverline_120cm_cct_function_of_incl\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_cct_function_of_incl-400x310.png\" alt=\"greentubes_silverline_120cm_cct_function_of_incl\" width=\"400\" height=\"310\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The measurement of CCT is measured for inclination angles up to 70\u00ba since then the illuminance value was decreased to very low values (&lt; 5 lux).<\/p>\n<p>The beam angle for the C0-C180 is 181\u00ba, meaning a 90.5\u00ba inclination angle. In this area the majority of the light is present. The variation in correlated color temperature in this area is &lt; 1 %.<\/p>\n<p>The beam angle for the C90-C270 is 107\u00ba, meaning a 53.5\u00ba inclination angle. In this area the majority of the light is present. The variation in correlated color temperature in this area is \u2248 1 %.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_par_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11634\" title=\"greentubes_silverline_120cm_par_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_par_spectra_at_1m_distance-400x230.png\" alt=\"greentubes_silverline_120cm_par_spectra_at_1m_distance\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>4.3<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>18.6<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.7<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 65 % (valid for the PAR wave length range of 400 &#8211; 700 nm). So maximally 65 % of the total of photons in the light is effectively used by the average plant (since the plant might not take 100 % of the photons at the frequency where its relative sensitivity is 100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_s_and_p_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11635\" title=\"greentubes_silverline_120cm_s_and_p_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_s_and_p_spectra_at_1m_distance-400x251.png\" alt=\"greentubes_silverline_120cm_s_and_p_spectra_at_1m_distance\" width=\"400\" height=\"251\" \/><\/a><br \/>\n<em>The power spectrum, sensitivity curves and resulting scotopic and photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 2.3<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website<\/a>.<\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_chromaticity.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11636\" title=\"greentubes_silverline_120cm_chromaticity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_chromaticity-400x374.png\" alt=\"greentubes_silverline_120cm_chromaticity\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is at a distance from the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a> (the black path in the graph).<\/p>\n<p>Its coordinates are x=0.3080 and y=0.3436.<\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>Herewith the image showing the CRI as well as how well different colors are represented (rendered). The higher the number, the better the resemblance with the color when a black body radiator would have been used (the sun, or an incandescent lamp). Practical information and also some critics about the CRI can be found on <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_cri.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-11637\" title=\"greentubes_silverline_120cm_cri\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_cri.png\" alt=\"greentubes_silverline_120cm_cri\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>The value of 84 is higher than 80 which is considered a minimum value for indoor usage.<\/p>\n<p>Note: the chromaticity difference is 0.0074 indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a>. There is no norm yet that states what the max deviation from white light is allowed to be.<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is determined. For this, the lamp voltage has been varied and its effect on the following light bulb parameters measured: illuminance E_v [lx], the lamppower P [W], the (Correlated) Color Temperature [K] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11638\" title=\"greentubes_silverline_120cm_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_voltagedependency-400x241.png\" alt=\"greentubes_silverline_120cm_voltagedependency\" width=\"400\" height=\"241\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power do vary when the voltage is varied, in a linear matter.<\/p>\n<p>When the voltage at 230 V varies with + and &#8211; 5 V, then the illuminance varies 2 %, so when abrupt voltage changes occur this effect is not visible in the illuminance output.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp is measured on illuminance E_v [lx], color temperature CT or correlated color temperature CCT [K], the lamppower P [W] and the luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_startupeffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11639\" title=\"greentubes_silverline_120cm_startupeffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_startupeffect-400x242.png\" alt=\"greentubes_silverline_120cm_startupeffect\" width=\"400\" height=\"242\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_startupeffect_end.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-11640\" title=\"greentubes_silverline_120cm_startupeffect_end\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/01\/greentubes_silverline_120cm_startupeffect_end-400x242.png\" alt=\"greentubes_silverline_120cm_startupeffect_end\" width=\"400\" height=\"242\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.<\/em><\/p>\n<p>The warm up time is about 5 minutes. During that time the illuminance increases to about 2.3 x the initial value.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Greentubes BV presents a 120 cm long tube light. It is a small fluorescent tube in a transparent plastic outer tube which serves as the housing. At the back side of the inner fluorescent tube a reflector is seated with a white color. At the back side (against the inner back side of the outer [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[23,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/4482"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=4482"}],"version-history":[{"count":10,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/4482\/revisions"}],"predecessor-version":[{"id":4484,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/4482\/revisions\/4484"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=4482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=4482"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=4482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}