{"id":5546,"date":"2010-08-18T05:11:17","date_gmt":"2010-08-18T10:11:17","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=5546"},"modified":"2010-08-20T20:43:43","modified_gmt":"2010-08-21T01:43:43","slug":"lle-1-x-led-tube-150-cm-in-ip65-luminaire-arm1x1500-ip65-g3-nw","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/08\/18\/lle-1-x-led-tube-150-cm-in-ip65-luminaire-arm1x1500-ip65-g3-nw\/","title":{"rendered":"LLE &#8211; 1 x led tube 150 cm in IP65 luminaire ARM1x1500-IP65-G3-NW"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/arm1x1500-ip65-g3-nw.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-16127\" title=\"arm1x1500-ip65-g3-nw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/arm1x1500-ip65-g3-nw-100x42.jpg\" alt=\"arm1x1500-ip65-g3-nw\" width=\"100\" height=\"42\" \/><\/a><!--supplier-not-set--> presents an IP65 luminaire with one led tube light in it. The tube  emits a cold white light.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\" target=\"_blank\">Eulumdat file<\/a>.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.  <!--more--><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>6088 K<\/td>\n<td>Cold white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>397 Cd<\/td>\n<td>Measured straight underneath the lamp<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulationindex\">Illuminance modulation index<\/a><\/td>\n<td>12 %<\/td>\n<td>Measured straight underneath the lamp. Is a measure for the amount of flickering.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>193 deg<\/td>\n<td>193\u00ba for the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C0-C180 plane<\/a> (crossing length direction of the tube) and 109\u00ba for the C90-C270 plane (length direction).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.olino.org\/us\/wp-admin\/#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>29.1 W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.96<\/td>\n<td>For every 1 kWh net power consumed, there has been 0.3 kVAhr for reactive power.<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>16 %<\/td>\n<td>Total Harmonic Distortion<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>1684 Lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>58 Lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>74<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.3207 and y=0.3266<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Bipin\" target=\"_blank\">FL-tube<\/a><\/td>\n<td>This Tube Light is connected directly to the grid voltage of 230 V AC.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>3.4 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the  light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.5 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its  consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>1.9<\/td>\n<td>This factor indicates the amount of times more efficient the light  of this light bulb is perceived under scotopic circumstances (low  environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>L x W x H external dimensions<\/td>\n<td>1575 x 85 x 95 mm<\/td>\n<td>External dimensions of the luminaire.<\/td>\n<\/tr>\n<tr>\n<td>L x W x H luminous area<\/td>\n<td>1560 x 75 x 40 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is  equal to the dimensions of the prismatic cover behind which the led tube emits light.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 26.5-27 deg C. The hottest temperature of the luminaire, there where the powersupply is seated, gets <a href=\"#T_metingen\" target=\"_self\">about 13 degrees hotter<\/a> than ambient.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: during the warm up time the illuminance decreases with 6 %.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: the power consumption and illuminance do not depend significantly when the voltage is varied from 200 &#8211; 250 V.<\/td>\n<\/tr>\n<tr>\n<td>Measurement report (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2010\/08\/arm1x1500-ip65-g3-nw_eng.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_eulumdat.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-1887\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16130\" title=\"lle_1x150_in_lum_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_summary2-400x135.png\" alt=\"lle_1x150_in_lum_summary2\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website.<\/p>\n<p>Please note that this overview table makes use of calculations, use  this data with care as explained on the OliNo site. E (lux) values are  not accurate, when within 5 x 1560 mm \u2248 7800 mm. Within this distance  from the lamp, the measured lux values willl be less than the computed  values in this overview as the measurements are then within the near  field of the lamp.<\/p>\n<p>Note II: the 50 % level for the C0-C180 plane is not valid, as the beamangle &gt; 180 degrees. So do not consider the negative values in the table.<\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/arm1x1500-ip65-g3-nw_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16131\" title=\"arm1x1500-ip65-g3-nw_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/arm1x1500-ip65-g3-nw_light_diagram-400x267.png\" alt=\"arm1x1500-ip65-g3-nw_light_diagram\" width=\"400\" height=\"267\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. The  direction or plane C0-C180 cuts the lamp in the direction crossing the  length direction of the tube, and the C90-C270 plane cuts the lamp in  the length direction.<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_pp_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16132\" title=\"lle_1x150_in_lum_pp_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_pp_avg-392x400.png\" alt=\"lle_1x150_in_lum_pp_avg\" width=\"392\" height=\"400\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the  light diagram given earlier. Also, in this graph the luminous intensity  is given in Cd. These averaged values are used (later) to compute the  lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16133\" title=\"lle_1x150_in_lum_ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_ev_dep_kantelhoek-400x211.png\" alt=\"lle_1x150_in_lum_ev_dep_kantelhoek\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement  results for each turn angle at that inclination angle. There normally  are differences in illuminance values for different turn angles. However  for further calculations the averaged values will be used. When using  the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 193\u00ba in the C0-C180 plane and 109\u00ba in the C90-C270 plane.<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.  The result of this computation for this light spot is a luminous flux of 1684 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 1684 Lm, and the power of the light bulb being 29.1 W, yields a luminous efficacy of 58 Lm\/W.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>A power factor of 0.96 means that for every 1 kWh net power consumed, a reactive component of 0.3 kVAr was needed.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>132 mA<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>29.1 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>30.3 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>0.96<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">the OliNo site<\/a> how this is obtained.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_u_i_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16134\" title=\"lle_1x150_in_lum_u_i_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_u_i_waveforms-400x222.png\" alt=\"lle_1x150_in_lum_u_i_waveforms\" width=\"400\" height=\"222\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/01\/02\/background-thd-and-iec-61000-3-22006-results-in-lamp-measurement-articles\" target=\"_blank\">explanation on the OliNo website<\/a>.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_harmonics.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16135\" title=\"lle_1x150_in_lum_harmonics\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_harmonics-400x219.png\" alt=\"lle_1x150_in_lum_harmonics\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the current waveform and checked against IEC61000-3-2:2006<\/em><\/p>\n<p>There are limits for the harmonics for lighting equipment &gt; 25 W which are fulfilled.<\/p>\n<p>The Total Harmonic Distortion of the current is computed as 16 %.<\/p>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/ir_0280.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16136\" title=\"ir_0280\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/ir_0280-400x300.jpg\" alt=\"ir_0280\" width=\"400\" height=\"300\" \/><\/a><\/em><\/p>\n<p><em><\/em><\/p>\n<p><em>The place of the power supplies is well visible<\/em><\/p>\n<p><em> <\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/ir_02821.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16137\" title=\"ir_02821\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/ir_02821-400x300.jpg\" alt=\"ir_02821\" width=\"400\" height=\"300\" \/><\/a><\/em><\/p>\n<p><em>Seen from the side of the armature.<\/em><\/p>\n<p>For the temperature measurement a piece of masking tape was not needed as the outer surface of the armature had a high emissivity.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>27 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>27 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir T335<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>0.5 m<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.7 mm<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>50 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> The outside of the luminaire has a high emissivity..<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16138\" title=\"lle_1x150_in_lum_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_powerspectrum_at_1m_distance-400x211.png\" alt=\"lle_1x150_in_lum_powerspectrum_at_1m_distance\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is about 6100 K which is cold white.<\/p>\n<p>This color temperature is measured straight underneath the light  bulb. Below a graph showing the color temperature for different  inclination angles.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_cct_function_of_incl.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16139\" title=\"lle_1x150_in_lum_cct_function_of_incl\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_cct_function_of_incl-400x310.png\" alt=\"lle_1x150_in_lum_cct_function_of_incl\" width=\"400\" height=\"310\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The measurement of CCT is measured for inclination angles up to 60\u00ba  (for the C90-C270 plane) as beyond that angle the illuminance values are very low (&lt; 5 lux). The C0-C180 plane has been measured up to 90\u00ba inclination angle<\/p>\n<p>The beam angle is maximally 193\u00ba, meaning a 96.5\u00ba inclination angle. In  this area most of the light is present. The variation in correlated  color temperature in the first 90\u00ba is \u2248 17 %.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_par_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16140\" title=\"lle_1x150_in_lum_par_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_par_spectra_at_1m_distance-400x230.png\" alt=\"lle_1x150_in_lum_par_spectra_at_1m_distance\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>3.4<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>14.6<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.5<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 66 % (valid for the PAR wave length range of  400 &#8211; 700 nm). So maximally 66 % of the total of photons in the light is  effectively used by the average plant (since the plant might not take  100 % of the photons at the frequency where its relative sensitivity is  100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_s_and_p_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16141\" title=\"lle_1x150_in_lum_s_and_p_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_s_and_p_spectra_at_1m_distance-400x251.png\" alt=\"lle_1x150_in_lum_s_and_p_spectra_at_1m_distance\" width=\"400\" height=\"251\" \/><\/a><\/p>\n<p><em>The power spectrum, sensitivity curves and resulting scotopic and  photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 1.9.<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website.<\/a><\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_chromaticity.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16142\" title=\"lle_1x150_in_lum_chromaticity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_chromaticity-400x374.png\" alt=\"lle_1x150_in_lum_chromaticity\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is inside the area designated with  class A. This Class A is an area that is defined for signal lamps, see  also <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Its coordinates are x=0.3207 and y=0.3266.<\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>Herewith the image showing the CRI as well as how well different  colors are represented (rendered). The higher the number, the better the  resemblance with the color when a black body radiator would have been  used (the sun, or an incandescent lamp). Practical information and also  some critics about the CRI can be found on <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\">the OliNo website<\/a>.  Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_cri.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-16143\" title=\"lle_1x150_in_lum_cri\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_cri.png\" alt=\"lle_1x150_in_lum_cri\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>The value of 74 is lower than 80 which is considered a minimum value for indoor usage.<\/p>\n<p>Note: the chromaticity difference is 0.0051 indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a>.  There is no norm yet that states what the max deviation from white  light is allowed to be. A reference with signal lights as a reference is  given in the <a href=\"kleursoort\" target=\"_self\">chromaticity<\/a> diagram.<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is  determined. For this, the lamp voltage has been varied and its effect on  the following light bulb parameters measured: illuminance E_v [lx], the  lamppower P [W] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16144\" title=\"lle_1x150_in_lum_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_voltagedependency-400x231.png\" alt=\"lle_1x150_in_lum_voltagedependency\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power do not vary significantly when the voltage is varied.<\/p>\n<p>When the voltage at 230 V varies with + and &#8211; 5 V, then the  illuminance varies &lt; 0.1 %, so when abrupt voltage changes occur this  effect is not visible in the illuminance output.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp  is measured on illuminance E_v [lx], the lamppower P [W] and the  luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_startupeffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16145\" title=\"lle_1x150_in_lum_startupeffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_startupeffect-400x231.png\" alt=\"lle_1x150_in_lum_startupeffect\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_startupeffect_end.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16146\" title=\"lle_1x150_in_lum_startupeffect_end\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_startupeffect_end-400x231.png\" alt=\"lle_1x150_in_lum_startupeffect_end\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.<\/em><\/p>\n<p>The warm up time is about one hour. During that time the the illuminance decreases with 6 %.<\/p>\n<h3><a name=\"modulationindex\">Measure of flickering<\/a><\/h3>\n<p>An analysis is done on the measure of flickering of the light output by this light bulb. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/12\/the-flickering-of-light-bulbs\" target=\"_blank\">the OliNo site<\/a> for more information.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_flicker_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16147\" title=\"lle_1x150_in_lum_flicker_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/06\/lle_1x150_in_lum_flicker_waveforms-400x212.png\" alt=\"lle_1x150_in_lum_flicker_waveforms\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The measure of fast illuminance variartion of the light of the light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>waarde<\/th>\n<th>eenheid<\/th>\n<\/tr>\n<tr>\n<td>Flicker frequency<\/td>\n<td>100.0<\/td>\n<td>Hz<\/td>\n<\/tr>\n<tr>\n<td>Illuminance modulation index<\/td>\n<td>12<\/td>\n<td>%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The illuminance modulation index is computed as: (max_Ev &#8211; min_Ev) \/ (max_Ev + min_Ev).<em><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>presents an IP65 luminaire with one led tube light in it. The tube emits a cold white light. This article shows the measurement results. Many parameters are also found in the Eulumdat file. See this overview for a comparison with other light bulbs.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5546"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=5546"}],"version-history":[{"count":7,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5546\/revisions"}],"predecessor-version":[{"id":5594,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5546\/revisions\/5594"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=5546"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=5546"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=5546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}