{"id":5703,"date":"2010-09-13T14:53:00","date_gmt":"2010-09-13T19:53:00","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=5703"},"modified":"2010-09-13T15:07:17","modified_gmt":"2010-09-13T20:07:17","slug":"endurance-test-ipled-smd60cm-8w-pw","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/09\/13\/endurance-test-ipled-smd60cm-8w-pw\/","title":{"rendered":"Endurance test IPLED SMD60CM-8W-PW"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2009\/09\/ip_t8_smd.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-7658\" title=\"ip_t8_smd\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2009\/09\/ip_t8_smd-100x30.jpg\" alt=\"ip_t8_smd\" width=\"100\" height=\"30\" \/><\/a> <a href=\"http:\/\/www.olino.org\/us\/ipled\" target=\"_blank\">IPLED<\/a> presents a 60 cm long ledtube, equipped with 120 leds.<\/p>\n<p>This lamp has been <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/01\/ipled-tube-smd60cm-8w-pw\" target=\"_blank\">measured at zero hours (new state)<\/a> before it went into the endurance test.<\/p>\n<p>This article presents the endurance test results.<\/p>\n<p><!--more--><\/p>\n<h3>Samenvatting meetgegevens<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>initially<\/th>\n<th>after endurance<\/th>\n<th>remarks<\/th>\n<\/tr>\n<tr>\n<td>Color Temperature<\/td>\n<td>5954 K<\/td>\n<td>5842 K<\/td>\n<td>Cold white<\/td>\n<\/tr>\n<tr>\n<td>Luminous Intensity I<sub>v<\/sub><\/td>\n<td>242 Cd<\/td>\n<td>223 Cd<\/td>\n<td>Went up at beginning and then down<\/td>\n<\/tr>\n<tr>\n<td>Beam Angle<\/td>\n<td>121 deg<\/td>\n<td>121 deg<\/td>\n<td>No variation.<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>7.7 W<\/td>\n<td>7.6 W<\/td>\n<td>Almost no variation<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/26\/explaining-the-power-factor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.86<\/td>\n<td>0.86<\/td>\n<td>No variation.<\/td>\n<\/tr>\n<tr>\n<td>Luminous Flux<\/td>\n<td>740 lm<\/td>\n<td>690 lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Luminous Efficacy<\/td>\n<td>96 lm\/W<\/td>\n<td>91 lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>CRI_Ra<\/td>\n<td>72<\/td>\n<td>70<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Coordinates Chromaticity Diagram<\/td>\n<td>x=0.3222 and y=0.3458<\/td>\n<td>x=0.3243 and y=0.3537<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Measurement Report (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/10\/Duurproef_IPled_60cmLedbuis_ENG.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Test duration and test environment<\/h3>\n<p>The lamp went into endurance test on 9 Oct 2009 and the test lasted until 23 June 2010.<\/p>\n<p>During this period of time the lamp has seen the following ambient temperature and ambient relative humidity (T and RH measurements were only started from Jan 2010).<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/screen-shot-2010-08-12-at-233736.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16986\" title=\"screen-shot-2010-08-12-at-233736\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/screen-shot-2010-08-12-at-233736-400x259.png\" alt=\"screen-shot-2010-08-12-at-233736\" width=\"400\" height=\"259\" \/><\/a><\/p>\n<p><em>Period 10 Jan 2010 &#8211; 3 May 2010<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/14mei2010-24juni2010.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16872\" title=\"14mei2010-24juni2010\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/14mei2010-24juni2010-400x261.png\" alt=\"14mei2010-24juni2010\" width=\"400\" height=\"261\" \/><\/a><\/p>\n<p><em>Period 14 May 2010 &#8211; 24 June 2010<\/em><\/p>\n<p>The ambient temperature close to the lamp varied between 9 &#8211; 33 deg C and the relative humidity between 25 &#8211; 58 %.<\/p>\n<h3>Variation of lamp parameters<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/ipled-60cm.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16873\" title=\"ipled-60cm\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/ipled-60cm-400x304.png\" alt=\"ipled-60cm\" width=\"400\" height=\"304\" \/><\/a><\/p>\n<p><em>The variation of the lamp parameters during the endurance test.<\/em><\/p>\n<p>See the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/09\/13\/endurance-test-setup\" target=\"_blank\">explanation on the OliNo site<\/a> for more on the test method.<\/p>\n<p>An extrapolation is done to get to the 70 % illuminance value. The illuminance value straight underneath the lamp is expected to be the good indicator of the total luminous flux. When this illuminance drops with 30 % then the luminous flux is expected to drop as well with 30 %. The assumption is here that the beam anlge and the radiation diagram remains the same. This has been checked, see also the initial table.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/extrapolatie_ipled_60cm.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16875\" title=\"extrapolatie_ipled_60cm\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/extrapolatie_ipled_60cm-400x305.png\" alt=\"extrapolatie_ipled_60cm\" width=\"400\" height=\"305\" \/><\/a><\/p>\n<p><em>Extrapolation of the illuminance.<\/em><\/p>\n<p>See the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/09\/13\/endurance-test-setup\" target=\"_blank\">explanation on the OliNo site<\/a> for more explanation and the link to the ASSIST document for the method of extrapolation.<\/p>\n<p>The result is 13,000 hours before the L70 is reached.<\/p>\n<h3>Color change<\/h3>\n<p>The color change (change in color coordinates) is measured during the test period.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/chromaticity_ipled60cm.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-16876\" title=\"chromaticity_ipled60cm\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/08\/chromaticity_ipled60cm-400x374.png\" alt=\"chromaticity_ipled60cm\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>Change in color coordinates during the endurance test.<\/em><\/p>\n<p>The color coordinates indicated with the red cross-hairs are the coordinates after 1000 burn hours. These are taken as reference. All measured color coordinates fall well within the 4 step Mac Adams ellipse.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>IPLED presents a 60 cm long ledtube, equipped with 120 leds. This lamp has been measured at zero hours (new state) before it went into the endurance test. This article presents the endurance test results.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[32,7],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5703"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=5703"}],"version-history":[{"count":4,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5703\/revisions"}],"predecessor-version":[{"id":5709,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5703\/revisions\/5709"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=5703"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=5703"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=5703"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}