{"id":5914,"date":"2010-10-19T06:36:10","date_gmt":"2010-10-19T11:36:10","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=5914"},"modified":"2010-10-19T08:18:59","modified_gmt":"2010-10-19T13:18:59","slug":"klv-ledverlichting-klv-hb90w-a_test","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/10\/19\/klv-ledverlichting-klv-hb90w-a_test\/","title":{"rendered":"KLV Ledverlichting &#8211; KLV-HB90W-A_test"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-19217\" title=\"KLV-HB90W-A_test\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test-89x100.jpg\" alt=\"\" width=\"89\" height=\"100\" \/><\/a><!--supplier-not-set--> presents a high bay ledlamp, emitting cold white light.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\" target=\"_blank\">Eulumdat file<\/a>.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><img decoding=\"async\" title=\"More...\" src=\"https:\/\/www.olino.org\/us\/wp-includes\/js\/tinymce\/plugins\/wordpress\/img\/trans.gif\" alt=\"\" \/><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>5410 K<\/td>\n<td>Cold white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>7005 Cd<\/td>\n<td>Measured straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulationindex\">Illuminance modulation index<\/a><\/td>\n<td>4 %<\/td>\n<td>Measured straight underneath the lamp. Is a measure for the amount of flickering.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>66 deg<\/td>\n<td>66\u00ba for all <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C-planes<\/a> since the lamp is symmetrical along its 1st axis.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.olino.org\/us\/wp-admin\/#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>96.1 W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.95<\/td>\n<td>For every 1 kWh net power consumed, there has been 0.3 kVAhr for reactive power.<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>9 %<\/td>\n<td>Total Harmonic Distortion<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>6647 Lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>69 Lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EUlabel\">EU-label classification<\/a><\/td>\n<td>B<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>72<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.3348 and y=0.3453<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td>230V<\/td>\n<td>This lamp is directly connected to the 230 V grid voltage.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>62 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the  light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.6 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its  consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>1.8<\/td>\n<td>This factor indicates the amount of times more efficient the light  of this light bulb is perceived under scotopic circumstances (low  environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>D x H external dimensions<\/td>\n<td>400 x 390 mm<\/td>\n<td>External dimensions of the lamp.<\/td>\n<\/tr>\n<tr>\n<td>D luminous area<\/td>\n<td>397 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is the  surface of the milk white plate at the front side.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 25.2-25.7 deg C.<\/p>\n<p>The temperature of the housing gets <a href=\"#T_metingen\" target=\"_self\">about 27 degrees hotter<\/a> than ambient temperature.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: during the warm up time the illuminance decreases with 5 % and the consumed power with 4 %.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: the power consumption and illuminance vary insignificantly, when the power voltage varies between 200-250 V.<\/td>\n<\/tr>\n<tr>\n<td>Measurement report (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_ENG.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_eulumdat.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19219\" title=\"KLV-HB90W-A_test_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_summary2-400x135.png\" alt=\"\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website.<\/p>\n<p>Please note that this overview table makes use of calculations, use  this data with care as explained on the OliNo site. E (lux) values are  not accurate, when within 5 x 400 mm \u2248 2000 mm. Within this distance from  the lamp, the measured lux values willl be less than the computed  values in this overview as the measurements are then within the near  field of the lamp.<\/p>\n<h3><a name=\"EUlabel\">EU Energy label classfication<\/a><\/h3>\n<p>With the measurement results of the luminous flux and the consumed power the classification on energy of this lamp is calculated. This information is requested in the EU for certain household lamps, see also the  <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/12\/eu-energy-label-for-lamps\" target=\"_blank\">OliNo site<\/a> that explains for which lamps it is requested, how the label looks like and what information it needs to contain.<\/p>\n<p>Herewith the labels for this lamp in color and black and white.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_EU_label_color.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19220\" title=\"KLV-HB90W-A_test_EU_label_color\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_EU_label_color-208x400.png\" alt=\"\" width=\"208\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label of this lamp<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_EU_label_bw.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-19221\" title=\"KLV-HB90W-A_test_EU_label_bw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_EU_label_bw-52x100.png\" alt=\"\" width=\"52\" height=\"100\" \/><\/a><\/p>\n<p><em>Label in black and white.<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19222\" title=\"KLV-HB90W-A_test_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_light_diagram-400x208.png\" alt=\"\" width=\"400\" height=\"208\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. All the  planes give (almost) the same results as the lamp is symmetrical along its 1st  axis.<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_PP_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19223\" title=\"KLV-HB90W-A_test_PP_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_PP_avg-400x209.png\" alt=\"\" width=\"400\" height=\"209\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the  light diagram given earlier. Also, in this graph the luminous intensity  is given in Cd.<\/p>\n<p>These averaged values are used (later) to compute the lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_Ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19224\" title=\"KLV-HB90W-A_test_Ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_Ev_dep_kantelhoek-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement  results for each turn angle at that inclination angle. There normally  are differences in illuminance values for different turn angles. However  for further calculations the averaged values will be used.<\/p>\n<p>When using the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 66\u00ba for all C-planes looked at.<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 6647 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 6647 Lm, and the power of the light bulb being 96.1 W, yields a luminous efficacy of 69 Lm\/W.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>A power factor of 0.95 means that for every 1 kWh net power consumed, a reactive component of 0.3 kVAr was needed.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>441 mA<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>96.1 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>101 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>0.95<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">the OliNo site<\/a> how this is obtained.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_U_I_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19225\" title=\"KLV-HB90W-A_test_U_I_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_U_I_waveforms-400x222.png\" alt=\"\" width=\"400\" height=\"222\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/01\/02\/background-thd-and-iec-61000-3-22006-results-in-lamp-measurement-articles\" target=\"_blank\">explanation on the OliNo website<\/a>.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_harmonics.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19226\" title=\"KLV-HB90W-A_test_harmonics\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_harmonics-400x219.png\" alt=\"\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the current waveform and checked against IEC61000-3-2:2006<\/em><\/p>\n<p>There are limits for the harmonics for lighting equipment &gt; 25 W which are fulfilled.<\/p>\n<p>The Total Harmonic Distortion of the current is computed as 9 %.<\/p>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0709.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19227\" title=\"IR_0709\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0709-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>Zoomed in on side and bottom view.<br \/>\n<\/em><\/p>\n<p>The side surface with the cool ribs has a high emissivity and is taken equal to that of masking tape (of 0.95).<\/p>\n<p>The back side has a lower emissivity which is seen as the masking tape is well visible in the IR image meaning that it reads a different temperature (reflects less).<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0712_em095NOK.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-19228\" title=\"IR_0712_em095NOK\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0712_em095NOK-100x75.jpg\" alt=\"\" width=\"100\" height=\"75\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0712_em065OK.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-19229\" title=\"IR_0712_em065OK\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0712_em065OK-100x75.jpg\" alt=\"\" width=\"100\" height=\"75\" \/><\/a><\/p>\n<p><em>Comparison of temperature reading to find emissivity<\/em><\/p>\n<p>The emissivity of the back material is about 0.65. It has less ability to radiate heat away. In this case the back side also has already a lower temperature than the side which makes it less critical.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0715.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19230\" title=\"IR_0715\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0715-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>The front side of the lamp, with the leds.<\/em><\/p>\n<p>The front side has a rough surface and the emissivity is here put at 0.95, equal to that of a piece of masking tape.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>26 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>26 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir T335<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.65 and 0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>0.2, 0.4 and 0.6 m<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.136 mm per 0.1 m distance<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>50 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> See the text for explanation.<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19231\" title=\"KLV-HB90W-A_test_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_powerspectrum_at_1m_distance-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is about 5400 K which is cold white.<\/p>\n<p>This color temperature is measured straight underneath the light  bulb. Below a graph showing the color temperature for different  inclination angles.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_cct_function_of_incl.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19232\" title=\"KLV-HB90W-A_test_cct_function_of_incl\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_cct_function_of_incl-400x310.png\" alt=\"\" width=\"400\" height=\"310\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The measurement of CCT is measured for inclination angles up to 50\u00ba. Beyond this angle the illuminance is very low (&lt; 5 lux).<\/p>\n<p>The beam angle is 66\u00ba, meaning a 33\u00ba inclination angle. In this area  most of the light is present. The variation in correlated color  temperature in this area is about 5 %.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_PAR_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19233\" title=\"KLV-HB90W-A_test_PAR_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_PAR_spectra_at_1m_distance-400x230.png\" alt=\"\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>62<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>58.8<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.6<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 65 % (valid for the PAR wave length range of  400 &#8211; 700 nm). So maximally 65 % of the total of photons in the light is  effectively used by the average plant (since the plant might not take  100 % of the photons at the frequency where its relative sensitivity is  100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_S_and_P_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19234\" title=\"KLV-HB90W-A_test_S_and_P_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_S_and_P_spectra_at_1m_distance-400x251.png\" alt=\"\" width=\"400\" height=\"251\" \/><\/a><br \/>\n<em>The power spectrum, sensitivity curves and resulting scotopic and  photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 1.8.<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website<\/a>.<\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_chromaticity.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19235\" title=\"KLV-HB90W-A_test_chromaticity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_chromaticity-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is inside the area of class A. This is an area defined for signal lamps, see  also <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Its coordinates are x=0.3348 and y=0.3453.<\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>Herewith the image showing the CRI as well as how well different  colors are represented (rendered). The higher the number, the better the  resemblance with the color when a black body radiator would have been  used (the sun, or an incandescent lamp). Practical information and also  some critics about the CRI can be found on <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_cri.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-19236\" title=\"KLV-HB90W-A_test_cri\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_cri.png\" alt=\"\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>The value of 72 is lower than to the value 80 which is considered a minimum value for indoor usage.<\/p>\n<p>Note: the chromaticity difference is 0.0020 indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a>.  There is no norm yet that states what the max deviation from white  light is allowed to be. A reference with signal lights as a reference is  given in the <a href=\"kleursoort\" target=\"_self\">chromaticity<\/a> diagram.<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is  determined. For this, the lamp voltage has been varied and its effect on  the following light bulb parameters measured: illuminance E_v [lx], the  lamppower P [W] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19237\" title=\"KLV-HB90W-A_test_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_voltagedependency-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power vary insignificantly when the voltage is varied.<\/p>\n<p>When the voltage at 230 V varies with + and &#8211; 5 V, then the  illuminance varies &lt; 0.1 %, so when abrupt voltage changes occur this  effect is not visible in the illuminance output.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp  is measured on illuminance E_v [lx], the lamppower P [W] and the  luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_startupEffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19238\" title=\"KLV-HB90W-A_test_startupEffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_startupEffect-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_startupEffect_end.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19239\" title=\"KLV-HB90W-A_test_startupEffect_end\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_startupEffect_end-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.<\/em><\/p>\n<p>The warm up time is about 60 minutes, during which the illuminance decreases with 5 % and the consumed power with 4 %.<\/p>\n<h3><a name=\"modulationindex\">Measure of flickering<\/a><\/h3>\n<p>An analysis is done on the measure of flickering of the light output by this light bulb. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/12\/the-flickering-of-light-bulbs\" target=\"_blank\">the OliNo site<\/a> for more information.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_Flicker_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19240\" title=\"KLV-HB90W-A_test_Flicker_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/KLV-HB90W-A_test_Flicker_waveforms-400x212.png\" alt=\"\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The measure of fast illuminance variation of the light of the light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>Flicker frequency<\/td>\n<td>99.9<\/td>\n<td>Hz<\/td>\n<\/tr>\n<tr>\n<td>Illuminance modulation index<\/td>\n<td>4<\/td>\n<td>%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The illuminance modulation index is computed as: (max_Ev &#8211; min_Ev) \/ (max_Ev + min_Ev).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>presents a high bay ledlamp, emitting cold white light. This article shows the measurement results. Many parameters are also found in the Eulumdat file. See this overview for a comparison with other light bulbs.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5914"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=5914"}],"version-history":[{"count":4,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5914\/revisions"}],"predecessor-version":[{"id":5916,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/5914\/revisions\/5916"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=5914"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=5914"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=5914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}