{"id":6039,"date":"2010-11-01T01:31:05","date_gmt":"2010-11-01T06:31:05","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=6039"},"modified":"2011-02-13T09:26:24","modified_gmt":"2011-02-13T14:26:24","slug":"ledverlichting-soest-lvs_c88_mr16_nichia_dimmable","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/11\/01\/ledverlichting-soest-lvs_c88_mr16_nichia_dimmable\/","title":{"rendered":"Ledverlichting Soest &#8211; LVS_C88_MR16_Nichia_Dimmable"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-19682\" title=\"LVS_C88_MR16_Nichia_Dimbr\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr-100x90.jpg\" alt=\"\" width=\"100\" height=\"90\" \/><\/a><!--supplier-not-set--> presents an led MR16 spotlamp that emits warm white light. The lamp contains a little ventilator to effectively remove the heat and is also dimmable with help of a 12 V DC dimmer.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the Eulumdat file.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><img decoding=\"async\" title=\"More...\" src=\"https:\/\/www.olino.org\/us\/wp-includes\/js\/tinymce\/plugins\/wordpress\/img\/trans.gif\" alt=\"\" \/><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>2898 K<\/td>\n<td>Warm white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>604 Cd<\/td>\n<td>Measured straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulationindex\">Illuminance modulation index<\/a><\/td>\n<td>6 %<\/td>\n<td>Measured straight underneath the lamp. Is a measure for the amount of flickering.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>27 deg<\/td>\n<td>27\u00ba for all <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C planes<\/a> as this lamp has a symmetry along the 1st axis.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.olino.org\/us\/wp-admin\/#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>9.4 W<\/td>\n<td>Note: the lamp current varied between 730 and 780 mA. Maybe the effect of the ventilator off anf on. At 730 mA the consumed power is 8.8 W.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>n.a.<\/td>\n<td>A DC power supply was used to test. This means that there is no blind power.<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>n.a. %<\/td>\n<td>Total Harmonic Distortion is not present due to the usage of a DC Voltage which results in a DC current.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>243 Lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>26 Lm\/W<\/td>\n<td>Note that a DC power supply has been used. This efficacy is for the led only excluding the efficacy of a power supply converting grid voltage to the voltage or current needed for the led. Normally a power supply or converter adds in-efficacy to the total system unless this lamp is to be connected to for instance a battery.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EUlabel\">EU-label classification<\/a><\/td>\n<td>B<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>67<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.4524 and y=0.4218<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Multifaceted_reflector\" target=\"_blank\">GU5.3\/MR16<\/a><\/td>\n<td>This lamp can connected to a 12 V DC or AC voltage. For this test a 12 V DC has been used.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>5.1 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the  light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.2 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its  consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>1.1<\/td>\n<td>This factor indicates the amount of times more efficient the light  of this light bulb is perceived under scotopic circumstances (low  environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>D x H external dimensions<\/td>\n<td>50 x 54 mm<\/td>\n<td>External dimensions of the lamp.<\/td>\n<\/tr>\n<tr>\n<td>D luminous area<\/td>\n<td>34 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is the surface of the smallest circle around the leds.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 22.7-22.9 deg C.<\/p>\n<p>The temperature of the housing gets <a href=\"#T_metingen\" target=\"_self\">about 22 degrees hotter<\/a> than ambient temperature.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: during the warm up time the illuminance decreases with about 6 % and the consumed power seems to increase with about 7 %, but this seems to depend on the on or off status of the ventilator.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: the power consumption and illuminance vary, when the power voltage varies between 200-250 V.<\/p>\n<p>The lamp is tested on <a href=\"#dimbaar\">dim-ability<\/a> with help of a 12 V DC dimmer and found well dim-able.<\/td>\n<\/tr>\n<tr>\n<td>Measurement report (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2010\/11\/LVS_C88_MR16_Nichia_Dimbr_ENG.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_eulumdat.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<tr>\n<td>IES file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_ies.ies\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19685\" title=\"LVS_C88_MR16_Nichia_Dimbr_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_summary2-400x134.png\" alt=\"\" width=\"400\" height=\"134\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website.<\/p>\n<p>Please note that this overview table makes use of calculations, use  this data with care as explained on the OliNo site. E (lux) values are  not accurate, when within 5 x 34 mm \u2248 200 mm. Within this distance from  the lamp, the measured lux values willl be less than the computed  values in this overview as the measurements are then within the near  field of the lamp.<\/p>\n<h3><a name=\"EUlabel\">EU Energy label classfication<\/a><\/h3>\n<p>With the measurement results of the luminous flux and the consumed power the classification on energy of this lamp is calculated. This information is requested in the EU for certain household lamps, see also the  <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/12\/eu-energy-label-for-lamps\" target=\"_blank\">OliNo site<\/a> that explains for which lamps it is requested, how the label looks like and what information it needs to contain.<\/p>\n<p>Herewith the labels for this lamp in color and black and white.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_EU_label_color.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19686\" title=\"LVS_C88_MR16_Nichia_Dimbr_EU_label_color\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_EU_label_color-208x400.png\" alt=\"\" width=\"208\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label of this lamp<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_EU_label_bw.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-19687\" title=\"LVS_C88_MR16_Nichia_Dimbr_EU_label_bw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_EU_label_bw-52x100.png\" alt=\"\" width=\"52\" height=\"100\" \/><\/a><\/p>\n<p><em>Label in black and white.<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19688\" title=\"LVS_C88_MR16_Nichia_Dimbr_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_light_diagram-400x209.png\" alt=\"\" width=\"400\" height=\"209\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. The C0-C180 plane and C90-C270 give the same result as the lamp is semmetrical along its 1st axis.<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_PP_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19689\" title=\"LVS_C88_MR16_Nichia_Dimbr_PP_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_PP_avg-400x209.png\" alt=\"\" width=\"400\" height=\"209\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the  light diagram given earlier. Also, in this graph the luminous intensity  is given in Cd.<\/p>\n<p>These averaged values are used (later) to compute the lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_Ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19690\" title=\"LVS_C88_MR16_Nichia_Dimbr_Ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_Ev_dep_kantelhoek-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement  results for each turn angle at that inclination angle. There normally  are differences in illuminance values for different turn angles. However  for further calculations the averaged values will be used.<\/p>\n<p>When using the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 27\u00ba for the C0-C180 and the C90-C270 plane.<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 243 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 243 Lm, and the power of the light bulb being 9.4 W, yields a luminous efficacy of 26 Lm\/W.<\/p>\n<p>The reported efficacy is for the ledmodules only, without an eventual  power  supply needed to transform 230 V AC into 12 V DC. Such a power   supply would normally lead to additional power consumption.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>The lamp was used on DC power and therefore no blind currents.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>12.11 V DC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>0.778 A<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>9.4 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>n.a. VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>n.a.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0754.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19691\" title=\"IR_0754\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0754-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>Side view.<br \/>\n<\/em><\/p>\n<p>The aluminum measured directly gives the same temperature value (when the IR-camera is set to 0.95 emissivity) as the reading on the masking tape on the aluminum. This means that the aluminum has about an equal emissivity, so 0.95 was taken.This means the material is well capable of emitting heat via radiation.<\/p>\n<p>Besides that the lamp stays relatively cool thanks to the work of the ventilator that is build in.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0755.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19692\" title=\"IR_0755\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0755-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>Temperature image where the front is measured; the glass and the metal ring around it.<\/em><\/p>\n<p>The piece of masking tape is hardly visible on the metal ring. The ring measured directly gives then a equal value than measured indirectly (via the tape) so emissivity is taken 0.95.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>22 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>22 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir T335<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>0.2 m<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.136 mm per 0.1 m distance<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>50 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> See the text for explanation.<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19693\" title=\"LVS_C88_MR16_Nichia_Dimbr_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_powerspectrum_at_1m_distance-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is about 2900 K which is warm white.<\/p>\n<p>This color temperature is measured straight underneath the light  bulb. Below a graph showing the color temperature for different  inclination angles.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_cct_function_of_incl.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19694\" title=\"LVS_C88_MR16_Nichia_Dimbr_cct_function_of_incl\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_cct_function_of_incl-400x310.png\" alt=\"\" width=\"400\" height=\"310\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The measurement of CCT is measured for inclination angles up to 80\u00ba. Beyond this angle the illuminance is very low (&lt; 5 lux).<\/p>\n<p>The beam angle is 27\u00ba, meaning a 13.5\u00ba inclination angle. In this area  most of the light is present. The variation in correlated color  temperature in this area is about \u2248 3 %.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_PAR_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19695\" title=\"LVS_C88_MR16_Nichia_Dimbr_PAR_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_PAR_spectra_at_1m_distance-400x230.png\" alt=\"\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>5.1<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>2.0<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.2<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 62 % (valid for the PAR wave length range of  400 &#8211; 700 nm). So maximally 62 % of the total of photons in the light is  effectively used by the average plant (since the plant might not take  100 % of the photons at the frequency where its relative sensitivity is  100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_S_and_P_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19696\" title=\"LVS_C88_MR16_Nichia_Dimbr_S_and_P_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_S_and_P_spectra_at_1m_distance-400x251.png\" alt=\"\" width=\"400\" height=\"251\" \/><\/a><br \/>\n<em> <\/em><\/p>\n<p><em>The power spectrum, sensitivity curves and resulting scotopic and  photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 1.1.<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website<\/a>.<\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_chromaticity.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19697\" title=\"LVS_C88_MR16_Nichia_Dimbr_chromaticity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_chromaticity-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is inside the area of class B. This is an area defined for signal lamps, see  also <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Its coordinates are x=0.4524 and y=0.4218.<\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>Herewith the image showing the CRI as well as how well different  colors are represented (rendered). The higher the number, the better the  resemblance with the color when a black body radiator would have been  used (the sun, or an incandescent lamp). Practical information and also  some critics about the CRI can be found on <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_cri.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-19698\" title=\"LVS_C88_MR16_Nichia_Dimbr_cri\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_cri.png\" alt=\"\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>The value of 67 is lower than the value 80 which is considered a minimum value for indoor usage.<\/p>\n<p>Note: the chromaticity difference is 0.0049 indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a>.  There is no norm yet that states what the max deviation from white  light is allowed to be. A reference with signal lights as a reference is  given in the <a href=\"kleursoort\" target=\"_self\">chromaticity<\/a> diagram.<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is  determined. For this, the lamp voltage has been varied and its effect on  the following light bulb parameters measured: illuminance E_v [lx], the  lamppower P [W] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19699\" title=\"LVS_C88_MR16_Nichia_Dimbr_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_voltagedependency-400x279.png\" alt=\"\" width=\"400\" height=\"279\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 12 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power vary when the voltage is varied. It seems as if the efficacy is lowest at 12 V DC, however it can very well be that the ventilator was not running at the other voltages and that it was running at this measured 12 V. What was seen is that the power consumption was not stable but could vary about 0.6 W.<\/p>\n<p>When the voltage at 12 V varies with + and &#8211; 0.25 V, then the  illuminance varies \u2248 1 %, so when abrupt voltage changes occur this  effect is not visible in the illuminance output.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp  is measured on illuminance E_v [lx], the lamppower P [W] and the  luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_startupEffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19700\" title=\"LVS_C88_MR16_Nichia_Dimbr_startupEffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_startupEffect-400x279.png\" alt=\"\" width=\"400\" height=\"279\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. The 100 % level is put at the beginning.<\/em><\/p>\n<p>The warm up time is about 30 minutes during which the illuminance decreases 5.5 % (which is a little and possible thanks to the effect of thecooling of the ventilator) and the consumed power increased with about 7 % (measured separately). The fact that the power increased is maybe because first the ventilator was not (so much) on and then at the second measurement the ventilator was (full) on.<\/p>\n<h3><a name=\"modulationindex\">Measure of flickering<\/a><\/h3>\n<p>An analysis is done on the measure of flickering of the light output by this light bulb. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/12\/the-flickering-of-light-bulbs\" target=\"_blank\">the OliNo site<\/a> for more information.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_Flicker_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19701\" title=\"LVS_C88_MR16_Nichia_Dimbr_Flicker_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LVS_C88_MR16_Nichia_Dimbr_Flicker_waveforms-400x212.png\" alt=\"\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The measure of fast illuminance variation of the light of the light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>Flicker frequency<\/td>\n<td>573<\/td>\n<td>Hz<\/td>\n<\/tr>\n<tr>\n<td>Illuminance modulation index<\/td>\n<td>6<\/td>\n<td>%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The illuminance modulation index is computed as: (max_Ev &#8211; min_Ev) \/ (max_Ev + min_Ev).<\/p>\n<p>Note: with such a high flicker frequency any modulation will not be visible. <em> <\/em><\/p>\n<h3><a name=\"dimbaar\">Dim-ability<\/a><\/h3>\n<p>The lamp has been tested with help of a 12 V DC dimmer. More <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/31\/practical-measurements-on-a-12v-dc-dimmer-used-by-olino\" target=\"_blank\">explanation about this 12 V DC dimmer<\/a> can be found on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/dimbr_to_less_intensity1.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" title=\"dimbr_to_less_intensity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/dimbr_to_less_intensity1-400x242.png\" alt=\"\" width=\"400\" height=\"242\" \/><\/a><\/p>\n<p><em>Dimming with the 12 V DC dimmer.<\/em><\/p>\n<p>The efficacy increases a lot when dimming more and more. However it was not easy to measure very accurately at high dimming. Note that the power consumed by the lamp AND the dimmer is given here. So the set is quite efficient: at more dimming the led and dimmer have a higher afficacy.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/Screen-shot-2010-10-27-at-18.47.17-.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" title=\"Screen shot 2010-10-27 at 18.47.17\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/Screen-shot-2010-10-27-at-18.47.17--400x200.png\" alt=\"\" width=\"400\" height=\"200\" \/><\/a><\/p>\n<p><em>Dimming with the 12 V DC dimmer, zoomed in on the 0-100 % part<\/em><\/p>\n<p>The intensity can be set between 0 &#8211; 100 %.<\/p>\n<p>The consumed power decreases faster than the decrease of the light emitted. It indicates that the leds are more efficient at lower current values.<\/p>\n<p>The dimmer functions perfect.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>presents an led MR16 spotlamp that emits warm white light. The lamp contains a little ventilator to effectively remove the heat and is also dimmable with help of a 12 V DC dimmer. This article shows the measurement results. Many parameters are also found in the Eulumdat file. See this overview for a comparison with [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6039"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=6039"}],"version-history":[{"count":9,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6039\/revisions"}],"predecessor-version":[{"id":6044,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6039\/revisions\/6044"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=6039"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=6039"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=6039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}