{"id":6096,"date":"2010-11-08T13:32:31","date_gmt":"2010-11-08T18:32:31","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=6096"},"modified":"2010-11-19T01:30:01","modified_gmt":"2010-11-19T06:30:01","slug":"led-it-light-60x60cm-led-panel-40watt-cold-white","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/11\/08\/led-it-light-60x60cm-led-panel-40watt-cold-white\/","title":{"rendered":"LED IT LIGHT &#8211; 60x60cm LED panel 40Watt &#8211; cold white"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-19481\" title=\"LiL_ledpaneel\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel-100x75.jpg\" alt=\"\" width=\"100\" height=\"75\" \/><\/a><!--supplier-not-set--> presents a a led panel with dimensions of 600 x 600 mm and emitting cold white light.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the Eulumdat file.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><img decoding=\"async\" title=\"More...\" src=\"https:\/\/www.olino.org\/us\/wp-includes\/js\/tinymce\/plugins\/wordpress\/img\/trans.gif\" alt=\"\" \/><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>5511 K<\/td>\n<td>Cold white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>910 Cd<\/td>\n<td>Measured straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulationindex\">Illuminance modulation index<\/a><\/td>\n<td>27 %<\/td>\n<td>Measured straight underneath the lamp. Is a measure for the amount of flickering.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>119 deg<\/td>\n<td>119\u00ba for all the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C0-C180-plane<\/a> (cutting the lamp in two (not diagonally)) and 119\u00ba for the C90-C270 plane, which is pendendicular to the C0-C180 plane.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.olino.org\/us\/wp-admin\/#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>40.8 W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.88<\/td>\n<td>For every 1 kWh net power consumed, there has been 0.5 kVAhr for reactive power.<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>28 %<\/td>\n<td>Total Harmonic Distortion<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>2804 Lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>69 Lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EUlabel\">EU-label classification<\/a><\/td>\n<td>A<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>62<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.3325 and y=0.3613<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td>230V<\/td>\n<td>This lamp is connected directly to the 230 V grid voltage.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>7.2 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the  light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.5 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its  consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>1.8<\/td>\n<td>This factor indicates the amount of times more efficient the light  of this light bulb is perceived under scotopic circumstances (low  environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>L x W x H external dimensions<\/td>\n<td>596 x 596 x 50 mm<\/td>\n<td>External dimensions of the lamp.<\/td>\n<\/tr>\n<tr>\n<td>L x W luminous area<\/td>\n<td>552 x 552 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is the surface of the matte cover.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 23.5 &#8211; 25.3 deg C.<\/p>\n<p>The temperature of the housing gets <a href=\"#T_metingen\" target=\"_self\">about 5 degrees hotter<\/a> than ambient temperature. The power supply at the back side gets hotter.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: during the warm up time the illuminance and consumed power vary less than 5 %.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: the power consumption and illuminance vary insignificantly, when the power voltage varies between 200-250 V.<\/p>\n<p>At the end of the article <a href=\"#foto\" target=\"_self\">an additional photo<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Measurement report (PDF)<\/td>\n<td>tbc<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_eulumdat.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19483\" title=\"LiL_ledpaneel_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_summary2-400x135.png\" alt=\"\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website.<\/p>\n<p>Please note that this overview table makes use of calculations, use  this data with care as explained on the OliNo site. E (lux) values are  not accurate, when within 5 x 843 mm (diagonal measure) \u2248 4300 mm. Within this distance from  the lamp, the measured lux values willl be less than the computed  values in this overview as the measurements are then within the near  field of the lamp.<\/p>\n<h3><a name=\"EUlabel\">EU Energy label classfication<\/a><\/h3>\n<p>With the measurement results of the luminous flux and the consumed power the classification on energy of this lamp is calculated. This information is requested in the EU for certain household lamps, see also the  <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/12\/eu-energy-label-for-lamps\" target=\"_blank\">OliNo site<\/a> that explains for which lamps it is requested, how the label looks like and what information it needs to contain.<\/p>\n<p>Herewith the labels for this lamp in color and black and white.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_EU_label_color.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19484\" title=\"LiL_ledpaneel_EU_label_color\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_EU_label_color-208x400.png\" alt=\"\" width=\"208\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label of this lamp<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_EU_label_bw.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-19485\" title=\"LiL_ledpaneel_EU_label_bw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_EU_label_bw-52x100.png\" alt=\"\" width=\"52\" height=\"100\" \/><\/a><\/p>\n<p><em>Label in black and white.<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19486\" title=\"LiL_ledpaneel_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_light_diagram-400x212.png\" alt=\"\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. The C0-C180 plane is along the width direction of the lamp) and is the same as with the C90-C270 plane (along the length direction of the lamp).<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_PP_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19487\" title=\"LiL_ledpaneel_PP_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_PP_avg-400x209.png\" alt=\"\" width=\"400\" height=\"209\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the  light diagram given earlier. Also, in this graph the luminous intensity  is given in Cd.<\/p>\n<p>These averaged values are used (later) to compute the lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_Ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19488\" title=\"LiL_ledpaneel_Ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_Ev_dep_kantelhoek-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement  results for each turn angle at that inclination angle. There normally  are differences in illuminance values for different turn angles. However  for further calculations the averaged values will be used.<\/p>\n<p>When using the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 119\u00ba for the C0-C180 and 119\u00ba for the C90-C270 plane.<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 2804 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 2804 Lm, and the power of the light bulb being 40.8 W, yields a luminous efficacy of 69 Lm\/W.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>A power factor of 0.88 means that for every 1 kWh net power consumed, a reactive component of 0.5 kVAr was needed.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>202 mA<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>40.8 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>46.4 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>0.88<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">the OliNo site<\/a> how this is obtained.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_U_I_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19489\" title=\"LiL_ledpaneel_U_I_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_U_I_waveforms-400x222.png\" alt=\"\" width=\"400\" height=\"222\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/01\/02\/background-thd-and-iec-61000-3-22006-results-in-lamp-measurement-articles\" target=\"_blank\">explanation on the OliNo website<\/a>.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_harmonics.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19490\" title=\"LiL_ledpaneel_harmonics\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_harmonics-400x219.png\" alt=\"\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the current waveform and checked against IEC61000-3-2:2006 and A2:2009<br \/>\n<\/em><\/p>\n<p>There are limits for the harmonics for lighting equipment &gt; 25 W and these are just not fulfilled.<\/p>\n<p>Note: the used voltage has more harmonic content than allowed for a correct determination according to the norms mentioned. When applying a clean enough voltage (meaning a low harmonic content as described) it may well be possible that the current does fulfill the requirements. Therefore with this measurement it cannot be stated that the lamp&#8217;s current does not fulfill the requirement according to the norm.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_harmonics_voltage.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19491\" title=\"LiL_ledpaneel_harmonics_voltage\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_harmonics_voltage-400x219.png\" alt=\"\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the voltage waveform and checked against IEC61000-3-2:2006 and A2:2009<\/em><\/p>\n<p>The Total Harmonic Distortion of the current is computed as 28 %.<\/p>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0832.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19492\" title=\"IR_0832\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0832-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>The plate viewed from the back<\/em><em><br \/>\n<\/em><\/p>\n<p>The emissivity is the same as that of the masking tape, here taken as 0.95.<\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0833.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19493\" title=\"IR_0833\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0833-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/em><\/p>\n<p><em>The power supply unit at the back side of the panel is the hottest part<br \/>\n<\/em><\/p>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0835.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19494\" title=\"IR_0835\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/IR_0835-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/em><\/p>\n<p><em>The front of the led panel<\/em><\/p>\n<p>The emissivity of the front part of the lamp also is equal to that of the masking tape.<\/p>\n<p>Two binding bands are visible which were used to fix the lamp. In the determination of the luminous flux and the determination of the radiation diagram the correction for this covering effect of the two bands has been done. As a result the luminous flux and radiation diagram and intensity values are correct.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>24.5 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>24.5 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir T335<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>1 m<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.136 mm per 0.1 m distance<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>50 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> See the text for explanation.<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19495\" title=\"LiL_ledpaneel_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_powerspectrum_at_1m_distance-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is about 5500 K which is cold white.<\/p>\n<p>This color temperature is measured straight underneath the light  bulb. Below a graph showing the color temperature for different  inclination angles.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_cct_function_of_incl.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19496\" title=\"LiL_ledpaneel_cct_function_of_incl\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_cct_function_of_incl-400x310.png\" alt=\"\" width=\"400\" height=\"310\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The measurement of CCT is measured for inclination angles up to 80\u00ba. Beyond this angle the illuminance is very low (&lt; 5 lux).<\/p>\n<p>The beam angle is 119\u00ba, meaning a 59.5\u00ba inclination angle. In this area  most of the light is present. The variation in correlated color  temperature in this area is &lt; 1 %.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_PAR_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19497\" title=\"LiL_ledpaneel_PAR_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_PAR_spectra_at_1m_distance-400x230.png\" alt=\"\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>7.2<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>22.0<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.5<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 63 % (valid for the PAR wave length range of  400 &#8211; 700 nm). So maximally 63 % of the total of photons in the light is  effectively used by the average plant (since the plant might not take  100 % of the photons at the frequency where its relative sensitivity is  100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_S_and_P_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19498\" title=\"LiL_ledpaneel_S_and_P_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_S_and_P_spectra_at_1m_distance-400x251.png\" alt=\"\" width=\"400\" height=\"251\" \/><\/a><br \/>\n<em>The power spectrum, sensitivity curves and resulting scotopic and  photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 1.8.<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website<\/a>.<\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_chromaticity.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19499\" title=\"LiL_ledpaneel_chromaticity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_chromaticity-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is outside the area of class A. This is an area defined for signal lamps, see  also <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Its coordinates are x=0.3325 and y=0.3613.<\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>Herewith the image showing the CRI as well as how well different  colors are represented (rendered). The higher the number, the better the  resemblance with the color when a black body radiator would have been  used (the sun, or an incandescent lamp). Practical information and also  some critics about the CRI can be found on <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_cri.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-19500\" title=\"LiL_ledpaneel_cri\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_cri.png\" alt=\"\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>The value of 62 is lower than to the value 80 which is considered a minimum value for indoor usage.<\/p>\n<p>Note: the chromaticity difference is 0.0069 indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a>.  There is no norm yet that states what the max deviation from white  light is allowed to be. A reference with signal lights as a reference is  given in the <a href=\"kleursoort\" target=\"_self\">chromaticity<\/a> diagram.<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is  determined. For this, the lamp voltage has been varied and its effect on  the following light bulb parameters measured: illuminance E_v [lx], the  lamppower P [W] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19501\" title=\"LiL_ledpaneel_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_voltagedependency-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power vary insignificantly when the voltage is varied.<\/p>\n<p>When the voltage at 230 V varies with + and &#8211; 5 V, then the  illuminance varies &lt; 0.1 %, so when abrupt voltage changes occur this  effect is not visible in the illuminance output.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp  is measured on illuminance E_v [lx], the lamppower P [W] and the  luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_startupEffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19502\" title=\"LiL_ledpaneel_startupEffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_startupEffect-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_startupEffect_end.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19503\" title=\"LiL_ledpaneel_startupEffect_end\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_startupEffect_end-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.<\/em><\/p>\n<p>The warm up time is not defined as the illuminance and consumed power vary less than 5 %.<\/p>\n<h3><a name=\"modulationindex\">Measure of flickering<\/a><\/h3>\n<p>An analysis is done on the measure of flickering of the light output by this light bulb. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/12\/the-flickering-of-light-bulbs\" target=\"_blank\">the OliNo site<\/a> for more information.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_Flicker_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-19504\" title=\"LiL_ledpaneel_Flicker_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_Flicker_waveforms-400x212.png\" alt=\"\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The measure of fast illuminance variation of the light of the light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>Flicker frequency<\/td>\n<td>100<\/td>\n<td>Hz<\/td>\n<\/tr>\n<tr>\n<td>Illuminance modulation index<\/td>\n<td>27<\/td>\n<td>%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The illuminance modulation index is computed as: (max_Ev &#8211; min_Ev) \/ (max_Ev + min_Ev).<\/p>\n<h3><a name=\"foto\">Additional photo<\/a><\/h3>\n<p><em><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_back.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" title=\"LiL_ledpaneel_back\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/10\/LiL_ledpaneel_back-400x307.jpg\" alt=\"\" width=\"400\" height=\"307\" \/><\/a><\/em><\/p>\n<p><em>View on the back side of the lamp<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>presents a a led panel with dimensions of 600 x 600 mm and emitting cold white light. This article shows the measurement results. Many parameters are also found in the Eulumdat file. See this overview for a comparison with other light bulbs.<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6096"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=6096"}],"version-history":[{"count":5,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6096\/revisions"}],"predecessor-version":[{"id":6099,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6096\/revisions\/6099"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=6096"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=6096"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=6096"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}