{"id":6111,"date":"2010-11-10T09:40:24","date_gmt":"2010-11-10T14:40:24","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=6111"},"modified":"2010-11-10T10:10:05","modified_gmt":"2010-11-10T15:10:05","slug":"klv-ledverlichting-_-klv_listrip_rgb-test","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/11\/10\/klv-ledverlichting-_-klv_listrip_rgb-test\/","title":{"rendered":"KLV Ledverlichting _ KLV_LISTRIP_RGB test"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-20173\" title=\"KLV-LISTRIP-RGB_test\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test-100x92.jpg\" alt=\"\" width=\"100\" height=\"92\" \/><\/a><!--supplier-not-set-->presents a ledstring consisting of 30 RGB leds. With help of a controller the color of these leds is changed constantly. This is not something that could be stopped, so the measurement done has an averaged result of a lot of colors that changed during the measurement time. Some measurements were done several time to show the impact on this. These measurement results cannot be compared with the regular ones.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the Eulumdat file.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><img decoding=\"async\" title=\"More...\" src=\"https:\/\/www.olino.org\/us\/wp-includes\/js\/tinymce\/plugins\/wordpress\/img\/trans.gif\" alt=\"\" \/><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>n.a. K<\/td>\n<td>No correlated olor temperature could be measured as very often one color is sofar from the Plackian locus that a CCT cannot be calculated.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>8.9 Cd<\/td>\n<td>Measured straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulationindex\">Illuminance modulation index<\/a><\/td>\n<td>83 %<\/td>\n<td>Measured straight underneath the lamp. Is a measure for the amount of flickering.<\/p>\n<p>Note: this value depends on the color emitted. Some examples measured were 8, 22, 44, 83 %.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>141 deg<\/td>\n<td>141\u00ba for the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C0-C180-plane<\/a> (perpendicular to the length direction of the strip) and 134\u00ba for the C90-C270 plane, which is along the length direction of the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.olino.org\/us\/wp-admin\/#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>2.5 W<\/td>\n<td>The measured value depended on the color emitted and varied between 1.9 &#8211; 3.2 W.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.44<\/td>\n<td>For every 1 kWh net power consumed, there has been 2.1 kVAhr for reactive power.<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>78 %<\/td>\n<td>Total Harmonic Distortion<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>29 Lm<\/td>\n<td>This is an average value.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>12 Lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EUlabel\">EU-label classification<\/a><\/td>\n<td>B<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>n.a.<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>. Most of the times when the RGB leds were driven to emit one single color, a CRI could not be calculated.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.2003 and y=0.3023<\/td>\n<td>These are the averaged values during the complete set of illuminance measurements. But for every single measurement different x and y values are found.<\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td>230V<\/td>\n<td>This lamp is connected, via the adaptor, directly to the 230 V grid voltage.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>0.15 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the  light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.2 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its  consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>6.0<\/td>\n<td>This factor indicates the amount of times more efficient the light  of this light bulb is perceived under scotopic circumstances (low  environmental light level).<\/p>\n<p>This is a value for one measurement. But it changes when other colors are emitted.<\/td>\n<\/tr>\n<tr>\n<td>L x W x H external dimensions<\/td>\n<td>1000 x 10 x 3 mm<\/td>\n<td>External dimensions of the lamp.<\/td>\n<\/tr>\n<tr>\n<td>L x W luminous area<\/td>\n<td>1000 x 10 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is the surface of the flexible printed circuit board in which the leds are mounted.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 23.8 &#8211; 25.2 deg C.<\/p>\n<p>The temperature of the housing gets <a href=\"#T_metingen\" target=\"_self\">about 5degrees hotter<\/a> than ambient temperature.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: due to the changing of driving of leds, there is a lot of change in illumination and consumed power. During one hour of measurement, there was nothing seen as a general tendency so assumed is that there is no warm up effect.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: due to color changes the power and illuminance changes and much more than the variation seen during this relatively short voltage dependency measurement.<\/p>\n<p>At the end of this article there is an additional <a href=\"..\/..\/wp-admin\/post.php?action=edit&amp;post=19758#foto\">photo<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Measurement report (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_ENG.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_eulumdat.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Right click on icon and save the file.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20176\" title=\"KLV-LISTRIP-RGB_test_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_summary2-400x135.png\" alt=\"\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website.<\/p>\n<p>Note: the minimum distance for which the E [lux] values are valid, is dependent on the layout of the strip. Laid out straightly over its 1000 mm then the minimum distance should be 5 x 1000 mm to be able to consider this light source as a point source and to be able to compute the Ev values at even bigger distances according to an inverse square law. However this is not pratical.<\/p>\n<p>One other way to look at it is to observe 1 m of string length, which emits 29 lumen.<\/p>\n<p>Now if it is needed to get a rough idea of the illuminance on a small distance, say 50 cm, then consider 1\/5th of this distance of the lamp, here 10 cm. This part of the string will emit 1\/50 * 36 lx = 7.2 lx (at 50 cm). Now the string is longer than that so the remainder will add luminance to it, but always less as it is further away. With help of a program like Dialux this can all be calculated, use the eulumdat file for that as given in the table above.<\/p>\n<h3><a name=\"EUlabel\">EU Energy label classfication<\/a><\/h3>\n<p>With the measurement results of the luminous flux and the consumed power the classification on energy of this lamp is calculated. This information is requested in the EU for certain household lamps, see also the  <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/12\/eu-energy-label-for-lamps\" target=\"_blank\">OliNo site<\/a> that explains for which lamps it is requested, how the label looks like and what information it needs to contain.<\/p>\n<p>Herewith the labels for this lamp in color and black and white.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_EU_label_color.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20177\" title=\"KLV-LISTRIP-RGB_test_EU_label_color\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_EU_label_color-208x400.png\" alt=\"\" width=\"208\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label of this lamp<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_EU_label_bw.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20178\" title=\"KLV-LISTRIP-RGB_test_EU_label_bw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_EU_label_bw-52x100.png\" alt=\"\" width=\"52\" height=\"100\" \/><\/a><\/p>\n<p><em>Label in black and white.<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_position_lumFlux_Power_graph2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20247\" title=\"KLV-LISTRIP-RGB_test_position_lumFlux_Power_graph\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_position_lumFlux_Power_graph2-400x234.png\" alt=\"\" width=\"400\" height=\"234\" \/><\/a><\/p>\n<p><em>The lamp&#8217;s performance in the lumen-Watt field, with the energy efficacy fields indicated.<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20180\" title=\"KLV-LISTRIP-RGB_test_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_light_diagram-400x208.png\" alt=\"\" width=\"400\" height=\"208\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. The C0-C180 plane is along the width direction of the strip, meaning perpendicular to its length) and is the same as that of the C90-C270 plane (along the length direction of the strip).<\/p>\n<p>The image shows many peaks, coming from the variation of the colors and intensity during the measurement.<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_PP_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20181\" title=\"KLV-LISTRIP-RGB_test_PP_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_PP_avg-400x209.png\" alt=\"\" width=\"400\" height=\"209\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the  light diagram given earlier. Also, in this graph the luminous intensity  is given in Cd.<\/p>\n<p>These averaged values are used (later) to compute the lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20182\" title=\"KLV-LISTRIP-RGB_test_Ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Ev_dep_kantelhoek-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement  results for each turn angle at that inclination angle. There normally  are differences in illuminance values for different turn angles. However  for further calculations the averaged values will be used.<\/p>\n<p>When using the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 141\u00ba for the C0-C180 and 133\u00ba for the C90-C270 plane.<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 29 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 29 Lm, and the power of the light bulb being 2.5 W (this is the average value, the extremes were 1.9 W and 3.2 W), yields a luminous efficacy of 12 Lm\/W.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>A power factor of 0.44 means that for every 1 kWh net power consumed, a reactive component of 2.1 kVAr was needed.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>25 mA<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>2.5W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>5.8 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>0.44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">the OliNo site<\/a> how this is obtained.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_U_I_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20183\" title=\"KLV-LISTRIP-RGB_test_U_I_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_U_I_waveforms-400x222.png\" alt=\"\" width=\"400\" height=\"222\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/01\/02\/background-thd-and-iec-61000-3-22006-results-in-lamp-measurement-articles\" target=\"_blank\">explanation on the OliNo website<\/a>.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_harmonics.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20185\" title=\"KLV-LISTRIP-RGB_test_harmonics\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_harmonics-400x219.png\" alt=\"\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the current waveform and checked against IEC61000-3-2:2006 and A2:2009<br \/>\n<\/em><\/p>\n<p>There are no limits for the harmonics for lighting equipment &lt;= 25 W.<\/p>\n<p>The Total Harmonic Distortion of the current is computed as 78 %.<\/p>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/IR_0786.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20186\" title=\"IR_0786\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/IR_0786-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em> <\/em><\/p>\n<p><em>Zoomed in on the ledstring<\/em><\/p>\n<p>The emissivity of the silicone material is taken to be 0.95.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/IR_0787.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20187\" title=\"IR_0787\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/IR_0787-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>The controller left and the power supply unit right<br \/>\n<\/em><\/p>\n<p>All these components have a rough surface so their emissivity is taken high, 0.95.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>24 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>24 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir T335<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>0.4<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.136 mm per 0.1 m distance<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>50 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> See the text for explanation.<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20188\" title=\"KLV-LISTRIP-RGB_test_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_powerspectrum_at_1m_distance-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is not measurable since most of the times the ledstring emits a colored light for which a correlated color temperature is not defined. The given spectrum here is the spectrum of a point in time, at a certain color.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_PAR_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20189\" title=\"KLV-LISTRIP-RGB_test_PAR_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_PAR_spectra_at_1m_distance-400x230.png\" alt=\"\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>0.15<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>0.5<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.2<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 77 % (valid for the PAR wave length range of  400 &#8211; 700 nm). So maximally 77 % of the total of photons in the light is  effectively used by the average plant (since the plant might not take  100 % of the photons at the frequency where its relative sensitivity is  100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_S_and_P_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20190\" title=\"KLV-LISTRIP-RGB_test_S_and_P_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_S_and_P_spectra_at_1m_distance-400x251.png\" alt=\"\" width=\"400\" height=\"251\" \/><\/a><br \/>\n<em>The power spectrum, sensitivity curves and resulting scotopic and  photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 6.0. This is the value for this color (but the colors change).<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website<\/a>.<\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_aceraged.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20191\" title=\"KLV-LISTRIP-RGB_test_chromaticity_aceraged\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_aceraged-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is outside the area of class A. This is an area defined for signal lamps, see  also <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Its coordinates averaged are x=0.2003 and y=0.3023.<\/p>\n<p>Herewith a number of measurements that show that the color point (chromaticity coordinates) is covering a wide area.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_3.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20192\" title=\"KLV-LISTRIP-RGB_test_chromaticity_3\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_3-100x93.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_6.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20193\" title=\"KLV-LISTRIP-RGB_test_chromaticity_6\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_6-100x93.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_7.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20194\" title=\"KLV-LISTRIP-RGB_test_chromaticity_7\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_7-100x93.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_8.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20195\" title=\"KLV-LISTRIP-RGB_test_chromaticity_8\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_8-100x93.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_9.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20196\" title=\"KLV-LISTRIP-RGB_test_chromaticity_9\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_chromaticity_9-100x93.png\" alt=\"\" width=\"100\" height=\"93\" \/><\/a><\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>The CRI is not possible to calculate, as very often the chromaticity coordinates of the light is sofar from the Plackian locus that a CCT nor CRI can be calculated..<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is  determined. For this, the lamp voltage has been varied and its effect on  the following light bulb parameters measured: illuminance E_v [lx], the  lamppower P [W] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20197\" title=\"KLV-LISTRIP-RGB_test_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_voltagedependency-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power vary when the voltage is varied. This is mostly due to the fact that with changing colors the consumed power as well as the illuminance vary.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp  is measured on illuminance E_v [lx], the lamppower P [W] and the  luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_startupEffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20198\" title=\"KLV-LISTRIP-RGB_test_startupEffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_startupEffect-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_startupEffect_end.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20199\" title=\"KLV-LISTRIP-RGB_test_startupEffect_end\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_startupEffect_end-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.<\/em><\/p>\n<p>There are a lot of variations, due to the fact that the color is changing and therewith the amount of leds that are one and therewith the consumed power and illuminance. Over an hour, the variaitons do not have a tendency so assumed is that there is no warm up effect. This is likely since the power of 1.9 &#8211; 3.2 W is distributed over 30 leds and there is hardly any heat generated.<\/p>\n<h3><a name=\"modulationindex\">Measure of flickering<\/a><\/h3>\n<p>An analysis is done on the measure of flickering of the light output by this light bulb. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/12\/the-flickering-of-light-bulbs\" target=\"_blank\">the OliNo site<\/a> for more information.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_1.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20200\" title=\"KLV-LISTRIP-RGB_test_Flicker_waveforms_1\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_1-100x53.png\" alt=\"\" width=\"100\" height=\"53\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20201\" title=\"KLV-LISTRIP-RGB_test_Flicker_waveforms_2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_2-100x53.png\" alt=\"\" width=\"100\" height=\"53\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_3.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20202\" title=\"KLV-LISTRIP-RGB_test_Flicker_waveforms_3\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_3-100x53.png\" alt=\"\" width=\"100\" height=\"53\" \/><\/a><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_4.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20203\" title=\"KLV-LISTRIP-RGB_test_Flicker_waveforms_4\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_Flicker_waveforms_4-100x53.png\" alt=\"\" width=\"100\" height=\"53\" \/><\/a><\/p>\n<p><em>The measure of fast illuminance variation of the light of the light bulb<\/em><\/p>\n<p>Depending on the color a number of illuminance modulation indexes were calculated.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>Flicker frequency<\/td>\n<td>180<\/td>\n<td>Hz<\/td>\n<\/tr>\n<tr>\n<td>Illuminance modulation index<\/td>\n<td>83, 8, 44, 22<\/td>\n<td>%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The illuminance modulation index is computed as: (max_Ev &#8211; min_Ev) \/ (max_Ev + min_Ev).<\/p>\n<p>The 180 Hz might be so high that modulation effects are not visible.<em> <\/em><\/p>\n<h3><a name=\"foto\">Extra foto<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_led.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20204\" title=\"KLV-LISTRIP-RGB_test_led\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/KLV-LISTRIP-RGB_test_led-400x137.jpg\" alt=\"\" width=\"400\" height=\"137\" \/><\/a><br \/>\n<em>Detail photo of the RGB led on the flexible printed circuit board<\/em><\/p>\n<p><em><br \/>\n<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>presents a ledstring consisting of 30 RGB leds. With help of a controller the color of these leds is changed constantly. This is not something that could be stopped, so the measurement done has an averaged result of a lot of colors that changed during the measurement time. Some measurements were done several time to [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6111"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=6111"}],"version-history":[{"count":4,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6111\/revisions"}],"predecessor-version":[{"id":18477,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6111\/revisions\/18477"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=6111"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=6111"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=6111"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}