{"id":6372,"date":"2010-12-17T13:28:54","date_gmt":"2010-12-17T18:28:54","guid":{"rendered":"http:\/\/www.olino.org\/us\/?p=6372"},"modified":"2011-02-13T17:37:35","modified_gmt":"2011-02-13T22:37:35","slug":"fledlight%c2%a9-led-panel-fl62-nw-i18-caba","status":"publish","type":"post","link":"https:\/\/olino.org\/blog\/us\/articles\/2010\/12\/17\/fledlight%c2%a9-led-panel-fl62-nw-i18-caba\/","title":{"rendered":"Fledlight\u00a9 &#8211; led panel FL62-NW-i18-CABA"},"content":{"rendered":"<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/FL62-NW-ixx-CABA.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignright size-thumbnail wp-image-20399\" title=\"FL62-NW-ixx-CABA\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/FL62-NW-ixx-CABA-100x57.jpg\" alt=\"\" width=\"100\" height=\"57\" \/><\/a> <a href=\"http:\/\/www.olino.org\/us\/fledlight.nl\" target=\"_blank\">Fledlight\u00a9<\/a> presents a a led panel that can be put into two different power positions. In this article the low power mode is measured (type: FL62-NW-i18-CABA, order number: 91101829188). The lamp emits a neutral white light and it has a prismatic transparent cover.<\/p>\n<p>This article shows the measurement results. Many parameters are also found in the Eulumdat file.<\/p>\n<p>See <a href=\"\/us\/articles\/2008\/09\/21\/overview-lamp-measurements\" target=\"_self\">this overview<\/a> for a comparison with other light bulbs.<\/p>\n<p><!--more--><img decoding=\"async\" title=\"More...\" src=\"https:\/\/www.olino.org\/us\/wp-includes\/js\/tinymce\/plugins\/wordpress\/img\/trans.gif\" alt=\"\" \/><\/p>\n<h3>Summary measurement data<\/h3>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>meas. result<\/th>\n<th>remark<\/th>\n<\/tr>\n<tr>\n<td><a href=\"#kleurtemperatuur\">Color temperature<\/a><\/td>\n<td>3993 K<\/td>\n<td>Neutral white<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtsterkte\">Luminous intensity I<sub>v<\/sub><\/a><\/td>\n<td>610 Cd<\/td>\n<td>Measured straight underneath the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#modulationindex\">Illuminance modulation index<\/a><\/td>\n<td>18 %<\/td>\n<td>Measured straight underneath the lamp. Is a measure for the amount of flickering.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#stralingshoek\">Beam angle<\/a><\/td>\n<td>88 deg<\/td>\n<td>82\u00ba for all the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">C0-C180-plane<\/a> (perpendicular to the length direction of the lamp) and 88\u00ba for the C90-C270 plane, which is along the length direction of the lamp.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/www.olino.org\/us\/wp-admin\/#electrical\" target=\"_self\">Power P<\/a><\/td>\n<td>17.5 W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power Factor<\/a><\/td>\n<td>0.94<\/td>\n<td>For every 1 kWh net power consumed, there has been 0.4 kVAhr for reactive power.<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>7 %<\/td>\n<td>Total Harmonic Distortion<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#lichtstroom\">Luminous flux<\/a><\/td>\n<td>1211 Lm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#efficientie\">Luminous efficacy<\/a><\/td>\n<td>69 Lm\/W<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><a href=\"#EUlabel\">EU-label classification<\/a><\/td>\n<td>A<\/td>\n<td>The energy class, from A (more efficient) to G (least efficient).<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#cri\">CRI_Ra<\/a><\/td>\n<td>78<\/td>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/Color_rendering_index\" target=\"_blank\">Color Rendering Index<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Coordinates <a href=\"#kleursoort\">chromaticity diagram<\/a><\/td>\n<td>x=0.3831 and y=0.3868<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Fitting<\/td>\n<td>230V<\/td>\n<td>This lamp is connected directly to the 230 V grid voltage.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-value<\/a><\/td>\n<td>5.3 \u03bcMol\/s\/m<sup>2<\/sup><\/td>\n<td>The number of photons seen by an average plant when it is lit by the  light of this light bulb. Value valid at 1 m distance from light bulb.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#PAR\">PAR-photon efficacy<\/a><\/td>\n<td>0.6 \u03bcMol\/s\/W<sub>e<\/sub><\/td>\n<td>The toal emitted number of photons by this light, divided by its  consumption in W. It indicates a kind of efficacy in generating photons.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"#S\/P-ratio\">S\/P ratio<\/a><\/td>\n<td>1.6<\/td>\n<td>This factor indicates the amount of times more efficient the light  of this light bulb is perceived under scotopic circumstances (low  environmental light level).<\/td>\n<\/tr>\n<tr>\n<td>L x W x H external dimensions<\/td>\n<td>650 x 255 x 38 mm<\/td>\n<td>External dimensions of the lamp.<\/td>\n<\/tr>\n<tr>\n<td>L x W luminous area<\/td>\n<td>610 x 173 mm<\/td>\n<td>Dimensions of the luminous area (used in Eulumdat file). This is the surface of the prismatic cover.<\/td>\n<\/tr>\n<tr>\n<td>General remarks<\/td>\n<td><\/td>\n<td>The ambient temperature during the whole set of measurements was 22.8-24.5 deg C.<\/p>\n<p>The temperature of the housing gets <a href=\"#T_metingen\" target=\"_self\">about 22 degrees hotter<\/a> than ambient temperature, at the front of the luminaire, there where the power supply is seated. The rest of the front plate only gets about 5 degrees hotter than ambient.<\/p>\n<p><a href=\"#heatup-effect\">Warm up effect<\/a>: during the warm up time the illuminance decreases with less than 5 % and the consumed power with about 4 %.<\/p>\n<p><a href=\"#spanningsafhankelijkheid\">Voltage dependency<\/a>: the power consumption and illuminance vary insignificantly, when the power voltage varies between 200-250 V.<\/p>\n<p>At the end of the article <a href=\"#foto\" target=\"_self\">an additional photo<\/a>.<\/td>\n<\/tr>\n<tr>\n<td>Meetrapport (PDF)<\/td>\n<td><a href=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_ENG.pdf\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-854\" title=\"olino-pdf\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/01\/olino-pdf.jpg\" alt=\"olino-pdf\" width=\"43\" height=\"60\" \/><\/a><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Eulumdat file<\/td>\n<td><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_eulumdat1.ldt\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-1887\" title=\"olino_eulumdat\" src=\"http:\/\/www.olino.org\/us\/wp-content\/uploads\/2009\/05\/olino_eulumdat.png\" alt=\"olino_eulumdat\" width=\"70\" height=\"52\" \/><\/a><\/td>\n<td>Rechtsklik op het icoon en sla het bestand op.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Overview table<\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_summary2.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20987\" title=\"FL62-NW-i18-CABA_2_summary2\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_summary2-400x135.png\" alt=\"\" width=\"400\" height=\"135\" \/><\/a><\/p>\n<p>The <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#summary_table\" target=\"_blank\">overview table<\/a> is explained on the OliNo website.<\/p>\n<p>Please note that this overview table makes use of calculations, use  this data with care as explained on the OliNo site. E (lux) values are  not accurate, when within 5 x 634 mm (diagonal measure) \u2248 3200 mm. Within this distance from  the lamp, the measured lux values willl be less than the computed  values in this overview as the measurements are then within the near  field of the lamp.<\/p>\n<h3><a name=\"EUlabel\">EU Energy label classfication<\/a><\/h3>\n<p>With the measurement results of the luminous flux and the consumed power the classification on energy of this lamp is calculated. This information is requested in the EU for certain household lamps, see also the  <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/10\/12\/eu-energy-label-for-lamps\" target=\"_blank\">OliNo site<\/a> that explains for which lamps it is requested, how the label looks like and what information it needs to contain.<\/p>\n<p>Herewith the labels for this lamp in color and black and white.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_EU_label_color.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20988\" title=\"FL62-NW-i18-CABA_2_EU_label_color\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_EU_label_color-208x400.png\" alt=\"\" width=\"208\" height=\"400\" \/><\/a><\/p>\n<p><em>EU energy label of this lamp<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_EU_label_bw.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-thumbnail wp-image-20989\" title=\"FL62-NW-i18-CABA_2_EU_label_bw\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_EU_label_bw-52x100.png\" alt=\"\" width=\"52\" height=\"100\" \/><\/a><\/p>\n<p><em>Label in black and white.<\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_position_lumFlux_Power_graph.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20990\" title=\"FL62-NW-i18-CABA_2_position_lumFlux_Power_graph\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_position_lumFlux_Power_graph-400x234.png\" alt=\"\" width=\"400\" height=\"234\" \/><\/a><\/p>\n<p><em>The lamp&#8217;s performance in the lumen-Watt field, with the energy efficacy fields indicated.<\/em><\/p>\n<h3><a name=\"lichtsterkte\"><\/a>Eulumdat light diagram<\/h3>\n<p>This light diagram below comes from the program <a href=\"http:\/\/sourceforge.net\/projects\/qlumedit\" target=\"_blank\">Qlumedit<\/a>, that extracts these diagrams from an <a href=\"http:\/\/www.helios32.com\/Eulumdat.htm\">Eulumdat<\/a> file. <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#light_diagram\" target=\"_blank\">It is explained<\/a> on the OliNo site.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_light_diagram.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20991\" title=\"FL62-NW-i18-CABA_2_light_diagram\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_light_diagram-400x212.png\" alt=\"\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The light diagram giving the radiation pattern.<\/em><\/p>\n<p>It indicates the luminous intensity around the light bulb. The C0-C180 plane is along the width direction of the lamp) and is somewhat smaller than the beam angle in the C90-C270 plane (along the length direction of the lamp).<\/p>\n<h3>Illuminance Ev at 1 m distance, or luminous intensity Iv<\/h3>\n<p>Herewith the plot of the <em>averaged<\/em> luminous intensity Iv as a function of the inclination angle with the light bulb.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_PP_avg.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20992\" title=\"FL62-NW-i18-CABA_2_PP_avg\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_PP_avg-400x209.png\" alt=\"\" width=\"400\" height=\"209\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Radiation_pattern\" target=\"_blank\">radiation pattern<\/a> of the light bulb.<\/em><\/p>\n<p>This radiation pattern is the average of the light output of the  light diagram given earlier. Also, in this graph the luminous intensity  is given in Cd.<\/p>\n<p>These averaged values are used (later) to compute the lumen output.<\/p>\n<p><a name=\"stralingshoek\"><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_Ev_dep_kantelhoek.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20993\" title=\"FL62-NW-i18-CABA_2_Ev_dep_kantelhoek\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_Ev_dep_kantelhoek-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>Intensity data of every measured turn angle at each inclination angle.<\/em><\/p>\n<p>This plot shows per inclination angle the intensity measurement  results for each turn angle at that inclination angle. There normally  are differences in illuminance values for different turn angles. However  for further calculations the averaged values will be used.<\/p>\n<p>When using the average values per inclination angle, the <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#stralingshoek\" target=\"_blank\">beam angle<\/a> can be computed, being 82\u00ba for the C0-C180 and 88\u00ba for the C90-C270 plane.<\/p>\n<h3><a name=\"lichtstroom\">Luminous flux<\/a><\/h3>\n<p>With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible <a href=\"\/us\/articles\/2008\/09\/29\/background-light-measurements#I_v_2_PHI\" target=\"_self\">to compute the luminous flux<\/a>.<\/p>\n<p>The result of this computation for this light spot is a luminous flux of 1211 Lm.<\/p>\n<h3><a name=\"efficientie\">Luminous efficacy<\/a><\/h3>\n<p>The luminous flux being 1211 Lm, and the power of the light bulb being 17.5 W, yields a luminous efficacy of 69 Lm\/W.<\/p>\n<h3><a name=\"electrical\">Electrical properties<\/a><\/h3>\n<p>A power factor of 0.94 means that for every 1 kWh net power consumed, a reactive component of 0.4 kVAr was needed.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>Lamp voltage<\/td>\n<td>230 VAC<\/td>\n<\/tr>\n<tr>\n<td>Lamp current<\/td>\n<td>81 mA<\/td>\n<\/tr>\n<tr>\n<td>Power P<\/td>\n<td>17.5 W<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/en.wikipedia.org\/wiki\/AC_power\" target=\"_blank\">Apparent power<\/a> S<\/td>\n<td>18.6 VA<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">Power factor<\/a><\/td>\n<td>0.94<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Of this light bulb the voltage across ad the resulting current through it are measured and graphed. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#powerfactor\" target=\"_blank\">the OliNo site<\/a> how this is obtained.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_U_I_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20994\" title=\"FL62-NW-i18-CABA_2_U_I_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_U_I_waveforms-400x222.png\" alt=\"\" width=\"400\" height=\"222\" \/><\/a><\/p>\n<p><em>Voltage across and current through the lightbulb<\/em><\/p>\n<p>This waveforms have been checked on requirements posed by the norm IEC 61000-3-2:2006 (including up to A2:2009). See also the <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/01\/02\/background-thd-and-iec-61000-3-22006-results-in-lamp-measurement-articles\" target=\"_blank\">explanation on the OliNo website<\/a>.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_harmonics.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20995\" title=\"FL62-NW-i18-CABA_2_harmonics\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_harmonics-400x219.png\" alt=\"\" width=\"400\" height=\"219\" \/><\/a><\/p>\n<p><em>Harmonics in in the current waveform and checked against IEC61000-3-2:2006 and A2:2009<br \/>\n<\/em><\/p>\n<p>There are no limits for the harmonics for lighting equipment &lt;= 25 W.<\/p>\n<p>The Total Harmonic Distortion of the current is computed as 7 %.<\/p>\n<h3><a name=\"T_metingen\">Temperature measurements lamp<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/IR_1012.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20996\" title=\"IR_1012\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/IR_1012-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/IR_1011.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20997\" title=\"IR_1011\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/IR_1011-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>Temperature measurement from the front<\/em><em><br \/>\n<\/em><\/p>\n<p>The prismatic cover is made of a sort of plastic which has a high emissivity. The hottest temperature is found there where the power supply is seated.<\/p>\n<p><em> <\/em><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/IR_1014.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20998\" title=\"IR_1014\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/IR_1014-400x300.jpg\" alt=\"\" width=\"400\" height=\"300\" \/><\/a><\/p>\n<p><em>Temperature measurement back side<br \/>\n<\/em><\/p>\n<p><em> <\/em><\/p>\n<p>The material of the housing has a high emissivity, and also is hottest there where the power supply is positioned.<\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<td>status lamp<\/td>\n<td>&gt; 2 hours on<\/td>\n<\/tr>\n<tr>\n<td>ambient temperature<\/td>\n<td>22 deg C<\/td>\n<\/tr>\n<tr>\n<td>reflected background temperature<\/td>\n<td>22 deg C<\/td>\n<\/tr>\n<tr>\n<td>camera<\/td>\n<td>Flir T335<\/td>\n<\/tr>\n<tr>\n<td>emissivity<\/td>\n<td>0.95<sup>(1)<\/sup><\/td>\n<\/tr>\n<tr>\n<td>measurement distance<\/td>\n<td>1 m<\/td>\n<\/tr>\n<tr>\n<td>IFOV<sub>geometric<\/sub><\/td>\n<td>0.136 mm per 0.1 m distance<\/td>\n<\/tr>\n<tr>\n<td>NETD (thermal sensitivity)<\/td>\n<td>50 mK<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><sup>(1)<\/sup> See the text for explanation.<\/p>\n<h3><a name=\"kleurtemperatuur\">Color temperature and Spectral power distribution<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_powerspectrum_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20999\" title=\"FL62-NW-i18-CABA_2_powerspectrum_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_powerspectrum_at_1m_distance-400x211.png\" alt=\"\" width=\"400\" height=\"211\" \/><\/a><\/p>\n<p><em>The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance.<\/em><\/p>\n<p>The measured color temperature is about 4000 K which is neutral white.<\/p>\n<p>This color temperature is measured straight underneath the light  bulb. Below a graph showing the color temperature for different  inclination angles.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_cct_function_of_incl.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21000\" title=\"FL62-NW-i18-CABA_2_cct_function_of_incl\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_cct_function_of_incl-400x310.png\" alt=\"\" width=\"400\" height=\"310\" \/><\/a><\/p>\n<p><em>Color temperature as a function of inclination angle.<\/em><\/p>\n<p>The measurement of CCT is measured for inclination angles up to 75\u00ba. Beyond this angle the illuminance is very low (&lt; 5 lux).<\/p>\n<p>The beam angle is 88\u00ba, meaning a 44\u00ba inclination angle. In this area  most of the light is present. The variation in correlated color  temperature in this area is 2 %.<\/p>\n<h3><a name=\"PAR\">PAR value and PAR spectrum<\/a><\/h3>\n<p>To make a statement how well the light of this light bulb is for growing plants, the PAR-area needs to be determined. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#PAR\" target=\"_blank\">the OliNo website <\/a>how this all is determined and the explanation of the graph.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_PAR_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21001\" title=\"FL62-NW-i18-CABA_2_PAR_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_PAR_spectra_at_1m_distance-400x230.png\" alt=\"\" width=\"400\" height=\"230\" \/><\/a><\/p>\n<p><em>The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>PAR-number<\/td>\n<td>5.3<\/td>\n<td>\u03bcMol\/s\/m\u00b2<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon current<\/td>\n<td>10.6<\/td>\n<td>\u03bcMol\/s<\/td>\n<\/tr>\n<tr>\n<td>PAR-photon efficacy<\/td>\n<td>0.6<\/td>\n<td>\u03bcMol\/s\/W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PAR efficiency is 64 % (valid for the PAR wave length range of  400 &#8211; 700 nm). So maximally 64 % of the total of photons in the light is  effectively used by the average plant (since the plant might not take  100 % of the photons at the frequency where its relative sensitivity is  100 %).<\/p>\n<h3><a name=\"S\/P-ratio\">S\/P ratio<\/a><\/h3>\n<p>The S\/P ratio and measurement is explained <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/10\/29\/background-measurement-data-lamp-measurement-articles#S\/P-ratio\" target=\"_blank\">on the OliNo website<\/a>. Here the results are given.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_S_and_P_spectra_at_1m_distance.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21002\" title=\"FL62-NW-i18-CABA_2_S_and_P_spectra_at_1m_distance\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_S_and_P_spectra_at_1m_distance-400x251.png\" alt=\"\" width=\"400\" height=\"251\" \/><\/a><br \/>\n<em>The power spectrum, sensitivity curves and resulting scotopic and  photopic spectra (spectra energy content defined at 1 m distance).<\/em><\/p>\n<p>The S\/P ratio is 1.6.<\/p>\n<p>More info on S\/P ratio can be found <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/12\/14\/sp-ratio\" target=\"_blank\">on the OliNo website<\/a>.<\/p>\n<h3><a name=\"kleursoort\">Chromaticity diagram<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_chromaticity.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21003\" title=\"FL62-NW-i18-CABA_2_chromaticity\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_chromaticity-400x374.png\" alt=\"\" width=\"400\" height=\"374\" \/><\/a><\/p>\n<p><em>The <a href=\"http:\/\/en.wikipedia.org\/wiki\/Chromaticity\" target=\"_blank\">chromaticity space<\/a> and the position of the lamp&#8217;s color coordinates in it.<\/em><\/p>\n<p>The light coming from this lamp is inside the area of class A. This is an area defined for signal lamps, see  also <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/03\/06\/light-with-the-color-white\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Its coordinates are x=0.3831 and y=0.3868.<\/p>\n<h3><a name=\"cri\">Color Rendering Index (CRI) or also Ra<\/a><\/h3>\n<p>Herewith the image showing the CRI as well as how well different  colors are represented (rendered). The higher the number, the better the  resemblance with the color when a black body radiator would have been  used (the sun, or an incandescent lamp). Practical information and also  some critics about the CRI can be found on <a href=\"http:\/\/www.olino.org\/us\/articles\/2009\/11\/30\/a-close-look-at-the-color-rendering-index-cri-or-ra\" target=\"_blank\">the OliNo website<\/a>.<\/p>\n<p>Each color has an index Rx, and the first 8 indexes (R1 .. R8) are averaged to compute the Ra which is equivalent to the CRI.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_cri.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-21004\" title=\"FL62-NW-i18-CABA_2_cri\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_cri.png\" alt=\"\" width=\"367\" height=\"251\" \/><\/a><\/p>\n<p><em>CRI of the light of this lightbulb.<\/em><\/p>\n<p>The value of 78 is (marginally) lower than to the value 80 which is considered a minimum value for indoor usage.<\/p>\n<p>Note: the chromaticity difference is 0.0039 indicates the distance to the <a href=\"http:\/\/en.wikipedia.org\/wiki\/Planckian_locus\" target=\"_blank\">Planckian Locus<\/a>.  There is no norm yet that states what the max deviation from white  light is allowed to be. A reference with signal lights as a reference is  given in the <a href=\"#kleursoort\" target=\"_self\">chromaticity<\/a> diagram.<\/p>\n<h3><a name=\"spanningsafhankelijkheid\">Voltage dependency<\/a><\/h3>\n<p>The dependency of a number of lamp parameters on the lamp voltage is  determined. For this, the lamp voltage has been varied and its effect on  the following light bulb parameters measured: illuminance E_v [lx], the  lamppower P [W] and the luminous efficacy [Lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_voltagedependency.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21005\" title=\"FL62-NW-i18-CABA_2_voltagedependency\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_voltagedependency-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %.<\/em><\/p>\n<p>The illuminance and consumed power vary insignificantly when the voltage is varied.<\/p>\n<p>When the voltage at 230 V varies with + and &#8211; 5 V, then the  illuminance varies &lt; 0.1 %, so when abrupt voltage changes occur this  effect is not visible in the illuminance output.<\/p>\n<h3><a name=\"heatup-effect\">Warm up effects<\/a><\/h3>\n<p>After switch on of a cold lamp, the effect of heating up of the lamp  is measured on illuminance E_v [lx], the lamppower P [W] and the  luminous efficacy [lm\/W].<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_startupEffect.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21006\" title=\"FL62-NW-i18-CABA_2_startupEffect\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_startupEffect-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_startupEffect_end.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21007\" title=\"FL62-NW-i18-CABA_2_startupEffect_end\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_startupEffect_end-400x231.png\" alt=\"\" width=\"400\" height=\"231\" \/><\/a><\/p>\n<p><em>Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end.<\/em><\/p>\n<p>The warm up time is not defined as the illuminance and consumed power vary less than 5 %.<\/p>\n<h3><a name=\"modulationindex\">Measure of flickering<\/a><\/h3>\n<p>An analysis is done on the measure of flickering of the light output by this light bulb. See <a href=\"http:\/\/www.olino.org\/us\/articles\/2010\/04\/12\/the-flickering-of-light-bulbs\" target=\"_blank\">the OliNo site<\/a> for more information.<\/p>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_Flicker_waveforms.png\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-21008\" title=\"FL62-NW-i18-CABA_2_Flicker_waveforms\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/12\/FL62-NW-i18-CABA_2_Flicker_waveforms-400x212.png\" alt=\"\" width=\"400\" height=\"212\" \/><\/a><\/p>\n<p><em>The measure of fast illuminance variation of the light of the light bulb<\/em><\/p>\n<table border=\"0\">\n<tbody>\n<tr>\n<th>parameter<\/th>\n<th>value<\/th>\n<th>unit<\/th>\n<\/tr>\n<tr>\n<td>Flicker frequency<\/td>\n<td>100<\/td>\n<td>Hz<\/td>\n<\/tr>\n<tr>\n<td>Illuminance modulation index<\/td>\n<td>18<\/td>\n<td>%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The illuminance modulation index is computed as: (max_Ev &#8211; min_Ev) \/ (max_Ev + min_Ev).<\/p>\n<h3><a name=\"foto\">Additional photo<\/a><\/h3>\n<p><a href=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/FL62-NW-ixx-CABA_open.jpg\" class=\"thickbox no_icon\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-20424\" title=\"FL62-NW-ixx-CABA_open\" src=\"http:\/\/www.olino.org\/wp-content\/uploads\/2010\/11\/FL62-NW-ixx-CABA_open-400x133.jpg\" alt=\"\" width=\"400\" height=\"133\" \/><\/a><\/p>\n<p><em>View of the internal printed circuit board in which the leds are mounted<br \/>\n<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fledlight\u00a9 presents a a led panel that can be put into two different power positions. In this article the low power mode is measured (type: FL62-NW-i18-CABA, order number: 91101829188). The lamp emits a neutral white light and it has a prismatic transparent cover. This article shows the measurement results. Many parameters are also found in [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[7,20],"tags":[],"_links":{"self":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6372"}],"collection":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/comments?post=6372"}],"version-history":[{"count":4,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6372\/revisions"}],"predecessor-version":[{"id":6374,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/posts\/6372\/revisions\/6374"}],"wp:attachment":[{"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/media?parent=6372"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/categories?post=6372"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/olino.org\/blog\/us\/wp-json\/wp\/v2\/tags?post=6372"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}