Endurance test IPLED SMD60CM-8W-PW
Posted by Marcel van der Steen in Endurance Test, Led lights No Comments»IPLED presents a 60 cm long ledtube, equipped with 120 leds.
This lamp has been measured at zero hours (new state) before it went into the endurance test.
This article presents the endurance test results.
Samenvatting meetgegevens
parameter | initially | after endurance | remarks |
---|---|---|---|
Color Temperature | 5954 K | 5842 K | Cold white |
Luminous Intensity Iv | 242 Cd | 223 Cd | Went up at beginning and then down |
Beam Angle | 121 deg | 121 deg | No variation. |
Power P | 7.7 W | 7.6 W | Almost no variation |
Power Factor | 0.86 | 0.86 | No variation. |
Luminous Flux | 740 lm | 690 lm | |
Luminous Efficacy | 96 lm/W | 91 lm/W | |
CRI_Ra | 72 | 70 | |
Coordinates Chromaticity Diagram | x=0.3222 and y=0.3458 | x=0.3243 and y=0.3537 | |
Measurement Report (PDF) |
Test duration and test environment
The lamp went into endurance test on 9 Oct 2009 and the test lasted until 23 June 2010.
During this period of time the lamp has seen the following ambient temperature and ambient relative humidity (T and RH measurements were only started from Jan 2010).
Period 10 Jan 2010 – 3 May 2010
Period 14 May 2010 – 24 June 2010
The ambient temperature close to the lamp varied between 9 – 33 deg C and the relative humidity between 25 – 58 %.
Variation of lamp parameters
The variation of the lamp parameters during the endurance test.
See the explanation on the OliNo site for more on the test method.
An extrapolation is done to get to the 70 % illuminance value. The illuminance value straight underneath the lamp is expected to be the good indicator of the total luminous flux. When this illuminance drops with 30 % then the luminous flux is expected to drop as well with 30 %. The assumption is here that the beam anlge and the radiation diagram remains the same. This has been checked, see also the initial table.
Extrapolation of the illuminance.
See the explanation on the OliNo site for more explanation and the link to the ASSIST document for the method of extrapolation.
The result is 13,000 hours before the L70 is reached.
Color change
The color change (change in color coordinates) is measured during the test period.
Change in color coordinates during the endurance test.
The color coordinates indicated with the red cross-hairs are the coordinates after 1000 burn hours. These are taken as reference. All measured color coordinates fall well within the 4 step Mac Adams ellipse.