Endurance test – Led Luminaire EcoUnlimitLed (EUL) by Hato Lighting Solutions
Posted by Marcel van der Steen in Endurance Test No Comments»Hato Lighting Solutions presents an EUL-LED light, put in an endurance test.
This article presents the endurance test results. The test is running more than 11.500 hours.
Summary measurement data
parameter | initially | after endurance (10.000 hours) | remarks |
---|---|---|---|
Color Temperature | 3914 K | 3953 K | Neutral white |
Luminous Intensity Iv | 113 Cd | 112 Cd | |
Beam Angle | 360 deg | 360 deg | |
Power P | 14.2 W | 13.6 W | |
Power Factor | 0.93 | 0.93 | Test has been done with a PS that has been delivered with the lamp. |
Luminous Flux | 683 lm | 668 lm | |
Luminous Efficacy | 48 lm/W | 49 lm/W | |
CRI_Ra | 80 | 80 | |
Coordinates Chromaticity Diagram | x=0.3870 and y=0.3899 | x=0.3849 and y=0.3879 | |
Measurement report (PDF) | |||
Messprotocol (PDF) | |||
Rapport de mesurage (PDF) |
Test duration and test environment
The lamp went into endurance test on 26 April 2011 and the test continues. The summary table gives the results after 10.000 hours. The graphs below give the results up to 11.500 hours (Sept 2012).
During this period of time the lamp has seen the following ambient temperature and ambient relative humidity.
May 2011-August 2011.
Sept 2011 – Jan 2012.
Jan 2012 – Mar 2012.
April 2012 – July 2012.
July 2012 – Sept 2012.
The ambient temperature close to the lamp varied between 15-32 deg C and the relative humidity between 15-80 %.
Variation of lamp parameters
The variation of the lamp parameters during the endurance test.
See the explanation on the OliNo site for more on the test method.
An extrapolation is done to get to the 70 % illuminance value. The illuminance value straight underneath the lamp is expected to be the good indicator of the total luminous flux. When this illuminance drops with 30 % then the luminous flux is expected to drop as well with 30 %. The assumption is here that the beam angle and the radiation diagram remains the same.
Extrapolation of the illuminance.
See the explanation on the OliNo site for more explanation and the link to the ASSIST document for the method of extrapolation.
The result for L70 cannot be determined as the illuminance does not decrease.
Color change
The color change (change in color coordinates) is measured during the test period.
Change in color coordinates during the endurance test.
The color coordinates indicated with the red cross-hairs are the coordinates after 1000 burn hours. These are taken as reference. After 11.500 hours the color point remains well inside the 4-step McAdams ellipse.